Commit | Line | Data |
---|---|---|
3b8df390 GU |
1 | DT bindings for the Renesas R-Mobile System Controller |
2 | ||
3 | == System Controller Node == | |
4 | ||
5 | The R-Mobile System Controller provides the following functions: | |
6 | - Boot mode management, | |
7 | - Reset generation, | |
8 | - Power management. | |
9 | ||
10 | Required properties: | |
11 | - compatible: Should be "renesas,sysc-<soctype>", "renesas,sysc-rmobile" as | |
12 | fallback. | |
13 | Examples with soctypes are: | |
12920b02 | 14 | - "renesas,sysc-r8a73a4" (R-Mobile APE6) |
3b8df390 | 15 | - "renesas,sysc-r8a7740" (R-Mobile A1) |
fbaa5e69 | 16 | - "renesas,sysc-sh73a0" (SH-Mobile AG5) |
3b8df390 GU |
17 | - reg: Two address start and address range blocks for the device: |
18 | - The first block refers to the normally accessible registers, | |
19 | - the second block refers to the registers protected by the HPB | |
20 | semaphore. | |
21 | ||
22 | Optional nodes: | |
23 | - pm-domains: This node contains a hierarchy of PM domain nodes, which should | |
24 | match the Power Area Hierarchy in the Power Domain Specifications section of | |
25 | the device's datasheet. | |
26 | ||
27 | ||
28 | == PM Domain Nodes == | |
29 | ||
30 | Each of the PM domain nodes represents a PM domain, as documented by the | |
31 | generic PM domain bindings in | |
32 | Documentation/devicetree/bindings/power/power_domain.txt. | |
33 | ||
34 | The nodes should be named by the real power area names, and thus their names | |
35 | should be unique. | |
36 | ||
37 | Required properties: | |
38 | - #power-domain-cells: Must be 0. | |
39 | ||
40 | Optional properties: | |
41 | - reg: If the PM domain is not always-on, this property must contain the bit | |
42 | index number for the corresponding power area in the various Power | |
43 | Control and Status Registers. The parent's node must contain the | |
44 | following two properties: | |
45 | - #address-cells: Must be 1, | |
46 | - #size-cells: Must be 0. | |
47 | If the PM domain is always-on, this property must be omitted. | |
48 | ||
49 | ||
50 | Example: | |
51 | ||
52 | This shows a subset of the r8a7740 PM domain hierarchy, containing the | |
53 | C5 "always-on" domain, 2 of its subdomains (A4S and A4SU), and the A3SP domain, | |
54 | which is a subdomain of A4S. | |
55 | ||
56 | sysc: system-controller@e6180000 { | |
57 | compatible = "renesas,sysc-r8a7740", "renesas,sysc-rmobile"; | |
58 | reg = <0xe6180000 0x8000>, <0xe6188000 0x8000>; | |
59 | ||
60 | pm-domains { | |
61 | pd_c5: c5 { | |
62 | #address-cells = <1>; | |
63 | #size-cells = <0>; | |
64 | #power-domain-cells = <0>; | |
65 | ||
66 | pd_a4s: a4s@10 { | |
67 | reg = <10>; | |
68 | #address-cells = <1>; | |
69 | #size-cells = <0>; | |
70 | #power-domain-cells = <0>; | |
71 | ||
72 | pd_a3sp: a3sp@11 { | |
73 | reg = <11>; | |
74 | #power-domain-cells = <0>; | |
75 | }; | |
76 | }; | |
77 | ||
78 | pd_a4su: a4su@20 { | |
79 | reg = <20>; | |
80 | #power-domain-cells = <0>; | |
81 | }; | |
82 | }; | |
83 | }; | |
84 | }; | |
85 | ||
86 | ||
87 | == PM Domain Consumers == | |
88 | ||
89 | Hardware blocks belonging to a PM domain should contain a "power-domains" | |
90 | property that is a phandle pointing to the corresponding PM domain node. | |
91 | ||
92 | Example: | |
93 | ||
94 | tpu: pwm@e6600000 { | |
95 | compatible = "renesas,tpu-r8a7740", "renesas,tpu"; | |
96 | reg = <0xe6600000 0x100>; | |
97 | clocks = <&mstp3_clks R8A7740_CLK_TPU0>; | |