Commit | Line | Data |
---|---|---|
a5635912 LJ |
1 | Binding for Thermal Sensor driver for STMicroelectronics STi series of SoCs. |
2 | ||
3 | Required parameters: | |
4 | ------------------- | |
5 | ||
6 | compatible : st,<SoC>-<module>-thermal; should be one of: | |
7 | "st,stih415-sas-thermal", | |
8 | "st,stih415-mpe-thermal", | |
9 | "st,stih416-sas-thermal" | |
10 | "st,stih416-mpe-thermal" | |
11 | "st,stid127-thermal" or | |
12 | "st,stih407-thermal" | |
13 | according to the SoC type (stih415, stih416, stid127, stih407) | |
14 | and module type (sas or mpe). On stid127 & stih407 there is only | |
15 | one die/module, so there is no module type in the compatible | |
16 | string. | |
17 | clock-names : Should be "thermal". | |
18 | See: Documentation/devicetree/bindings/resource-names.txt | |
19 | clocks : Phandle of the clock used by the thermal sensor. | |
20 | See: Documentation/devicetree/bindings/clock/clock-bindings.txt | |
21 | ||
22 | Optional parameters: | |
23 | ------------------- | |
24 | ||
25 | reg : For non-sysconf based sensors, this should be the physical base | |
26 | address and length of the sensor's registers. | |
27 | interrupts : Standard way to define interrupt number. | |
28 | Interrupt is mandatory to be defined when compatible is | |
29 | "stih416-mpe-thermal". | |
30 | NB: For thermal sensor's for which no interrupt has been | |
31 | defined, a polling delay of 1000ms will be used to read the | |
32 | temperature from device. | |
33 | ||
34 | Example: | |
35 | ||
36 | temp1@fdfe8000 { | |
37 | compatible = "st,stih416-mpe-thermal"; | |
38 | reg = <0xfdfe8000 0x10>; | |
39 | clock-names = "thermal"; | |
40 | clocks = <&clk_m_mpethsens>; | |