thermal: ti-soc-thermal: Set the bandgap mask counter delay value
[deliverable/linux.git] / drivers / thermal / Kconfig
CommitLineData
203d3d4a
ZR
1#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
63c4ec90 6 tristate "Generic Thermal sysfs driver"
203d3d4a
ZR
7 help
8 Generic Thermal Sysfs driver offers a generic mechanism for
9 thermal management. Usually it's made up of one or more thermal
10 zone and cooling device.
543a9561 11 Each thermal zone contains its own temperature, trip points,
203d3d4a
ZR
12 cooling devices.
13 All platforms with ACPI thermal support can use this driver.
63c4ec90 14 If you want this support, you should say Y or M here.
16d75239 15
72e19897
ZR
16if THERMAL
17
16d75239 18config THERMAL_HWMON
ab92402a 19 bool
16d75239 20 depends on HWMON=y || HWMON=THERMAL
ab92402a 21 default y
6a92c366 22
72e19897
ZR
23choice
24 prompt "Default Thermal governor"
25 default THERMAL_DEFAULT_GOV_STEP_WISE
26 help
27 This option sets which thermal governor shall be loaded at
28 startup. If in doubt, select 'step_wise'.
29
30config THERMAL_DEFAULT_GOV_STEP_WISE
31 bool "step_wise"
9d185d04 32 select THERMAL_GOV_STEP_WISE
72e19897
ZR
33 help
34 Use the step_wise governor as default. This throttles the
35 devices one step at a time.
36
37config THERMAL_DEFAULT_GOV_FAIR_SHARE
38 bool "fair_share"
9d185d04 39 select THERMAL_GOV_FAIR_SHARE
72e19897
ZR
40 help
41 Use the fair_share governor as default. This throttles the
42 devices based on their 'contribution' to a zone. The
43 contribution should be provided through platform data.
44
45config THERMAL_DEFAULT_GOV_USER_SPACE
46 bool "user_space"
9d185d04 47 select THERMAL_GOV_USER_SPACE
72e19897
ZR
48 help
49 Select this if you want to let the user space manage the
50 lpatform thermals.
51
52endchoice
53
9d185d04 54config THERMAL_GOV_FAIR_SHARE
72e19897
ZR
55 bool "Fair-share thermal governor"
56 help
57 Enable this to manage platform thermals using fair-share governor.
58
9d185d04 59config THERMAL_GOV_STEP_WISE
72e19897
ZR
60 bool "Step_wise thermal governor"
61 help
62 Enable this to manage platform thermals using a simple linear
63
9d185d04 64config THERMAL_GOV_USER_SPACE
72e19897
ZR
65 bool "User_space thermal governor"
66 help
67 Enable this to let the user space manage the platform thermals.
68
02361418 69config CPU_THERMAL
bbf7fc88 70 bool "generic cpu cooling support"
72e19897 71 depends on CPU_FREQ
dd8e8c4a 72 select CPU_FREQ_TABLE
02361418
ADK
73 help
74 This implements the generic cpu cooling mechanism through frequency
f7188b3d
EV
75 reduction. An ACPI version of this already exists
76 (drivers/acpi/processor_thermal.c).
02361418
ADK
77 This will be useful for platforms using the generic thermal interface
78 and not the ACPI interface.
f7188b3d 79
02361418
ADK
80 If you want this support, you should say Y here.
81
e6e238c3
ADK
82config THERMAL_EMULATION
83 bool "Thermal emulation mode support"
84 help
85 Enable this option to make a emul_temp sysfs node in thermal zone
86 directory to support temperature emulation. With emulation sysfs node,
87 user can manually input temperature and test the different trip
88 threshold behaviour for simulation purpose.
89
8837295a
EV
90 WARNING: Be careful while enabling this option on production systems,
91 because userland can easily disable the thermal policy by simply
92 flooding this sysfs node with low temperature values.
93
ca3de46b
SG
94config IMX_THERMAL
95 tristate "Temperature sensor driver for Freescale i.MX SoCs"
96 depends on CPU_THERMAL
97 depends on MFD_SYSCON
98 depends on OF
99 help
100 Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
101 It supports one critical trip point and one passive trip point. The
102 cpufreq is used as the cooling device to throttle CPUs when the
103 passive trip is crossed.
104
6a92c366
VF
105config SPEAR_THERMAL
106 bool "SPEAr thermal sensor driver"
6a92c366 107 depends on PLAT_SPEAR
b9c7aff4 108 depends on OF
6a92c366
VF
109 help
110 Enable this to plug the SPEAr thermal sensor driver into the Linux
111 thermal framework
1e426ffd
KM
112
113config RCAR_THERMAL
114 tristate "Renesas R-Car thermal driver"
1e426ffd
KM
115 depends on ARCH_SHMOBILE
116 help
117 Enable this to plug the R-Car thermal sensor driver into the Linux
118 thermal framework
c48cbba6 119
7060aa36
NI
120config KIRKWOOD_THERMAL
121 tristate "Temperature sensor on Marvell Kirkwood SoCs"
122 depends on ARCH_KIRKWOOD
123 depends on OF
124 help
125 Support for the Kirkwood thermal sensor driver into the Linux thermal
126 framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
127
74ffa64c
AL
128config DOVE_THERMAL
129 tristate "Temperature sensor on Marvell Dove SoCs"
130 depends on ARCH_DOVE
131 depends on OF
132 help
133 Support for the Dove thermal sensor driver in the Linux thermal
134 framework.
135
aa1acb04 136config DB8500_THERMAL
137 bool "DB8500 thermal management"
138 depends on ARCH_U8500
139 default y
140 help
141 Adds DB8500 thermal management implementation according to the thermal
142 management framework. A thermal zone with several trip points will be
143 created. Cooling devices can be bound to the trip points to cool this
144 thermal zone if trip points reached.
145
fa0d654c
EG
146config ARMADA_THERMAL
147 tristate "Armada 370/XP thermal management"
148 depends on ARCH_MVEBU
149 depends on OF
150 help
151 Enable this option if you want to have support for thermal management
152 controller present in Armada 370 and Armada XP SoC.
153
aa1acb04 154config DB8500_CPUFREQ_COOLING
155 tristate "DB8500 cpufreq cooling"
156 depends on ARCH_U8500
157 depends on CPU_THERMAL
158 default y
159 help
160 Adds DB8500 cpufreq cooling devices, and these cooling devices can be
161 bound to thermal zone trip points. When a trip point reached, the
162 bound cpufreq cooling device turns active to set CPU frequency low to
163 cool down the CPU.
a56757af 164
d6d71ee4
JP
165config INTEL_POWERCLAMP
166 tristate "Intel PowerClamp idle injection driver"
167 depends on THERMAL
168 depends on X86
169 depends on CPU_SUP_INTEL
170 help
171 Enable this to enable Intel PowerClamp idle injection driver. This
172 enforce idle time which results in more package C-state residency. The
173 user interface is exposed via generic thermal framework.
174
f1a18a10
SP
175config X86_PKG_TEMP_THERMAL
176 tristate "X86 package temperature thermal driver"
b3ba0206 177 depends on X86_THERMAL_VECTOR
f1a18a10
SP
178 select THERMAL_GOV_USER_SPACE
179 default m
180 help
181 Enable this to register CPU digital sensor for package temperature as
182 thermal zone. Each package will have its own thermal zone. There are
183 two trip points which can be set by user to get notifications via thermal
184 notification methods.
185
eb982001
EV
186menu "Texas Instruments thermal drivers"
187source "drivers/thermal/ti-soc-thermal/Kconfig"
188endmenu
f157f596 189
c6821378
ADK
190menu "Samsung thermal drivers"
191depends on PLAT_SAMSUNG
192source "drivers/thermal/samsung/Kconfig"
193endmenu
194
72e19897 195endif
This page took 0.378733 seconds and 5 git commands to generate.