1 Standard Unit Suffixes for Property names
2
3 Properties which have a unit of measure are recommended to have a unit
4 suffix appended to the property name. The list below contains the
5 recommended suffixes. Other variations exist in bindings, but should not
6 be used in new bindings or added here. The inconsistency in the unit
7 prefixes is due to selecting the most commonly used variants.
8
9 It is also recommended to use the units listed here and not add additional
10 unit prefixes.
11
12 Time/Frequency
13 ----------------------------------------
14 -mhz : megahertz
15 -hz : Hertz (preferred)
16 -sec : seconds
17 -ms : milliseconds
18 -us : microseconds
19 -ns : nanoseconds
20
21 Distance
22 ----------------------------------------
23 -mm : millimeters
24
25 Electricity
26 ----------------------------------------
27 -microamp : micro amps
28 -ohms : Ohms
29 -micro-ohms : micro Ohms
30 -microvolt : micro volts
31
32 Temperature
33 ----------------------------------------
34 -celsius : Degrees Celsius
35 -millicelsius : Degreee milli-Celsius
36
37 Pressure
38 ----------------------------------------
39 -kpascal : kiloPascal