Merge tag 'dm-4.2-fixes-4' of git://git.kernel.org/pub/scm/linux/kernel/git/device...
[deliverable/linux.git] / Documentation / thermal / sysfs-api.txt
1 Generic Thermal Sysfs driver How To
2 ===================================
3
4 Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
5
6 Updated: 2 January 2008
7
8 Copyright (c) 2008 Intel Corporation
9
10
11 0. Introduction
12
13 The generic thermal sysfs provides a set of interfaces for thermal zone
14 devices (sensors) and thermal cooling devices (fan, processor...) to register
15 with the thermal management solution and to be a part of it.
16
17 This how-to focuses on enabling new thermal zone and cooling devices to
18 participate in thermal management.
19 This solution is platform independent and any type of thermal zone devices
20 and cooling devices should be able to make use of the infrastructure.
21
22 The main task of the thermal sysfs driver is to expose thermal zone attributes
23 as well as cooling device attributes to the user space.
24 An intelligent thermal management application can make decisions based on
25 inputs from thermal zone attributes (the current temperature and trip point
26 temperature) and throttle appropriate devices.
27
28 [0-*] denotes any positive number starting from 0
29 [1-*] denotes any positive number starting from 1
30
31 1. thermal sysfs driver interface functions
32
33 1.1 thermal zone device interface
34 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *type,
35 int trips, int mask, void *devdata,
36 struct thermal_zone_device_ops *ops,
37 const struct thermal_zone_params *tzp,
38 int passive_delay, int polling_delay))
39
40 This interface function adds a new thermal zone device (sensor) to
41 /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
42 thermal cooling devices registered at the same time.
43
44 type: the thermal zone type.
45 trips: the total number of trip points this thermal zone supports.
46 mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
47 devdata: device private data
48 ops: thermal zone device call-backs.
49 .bind: bind the thermal zone device with a thermal cooling device.
50 .unbind: unbind the thermal zone device with a thermal cooling device.
51 .get_temp: get the current temperature of the thermal zone.
52 .get_mode: get the current mode (enabled/disabled) of the thermal zone.
53 - "enabled" means the kernel thermal management is enabled.
54 - "disabled" will prevent kernel thermal driver action upon trip points
55 so that user applications can take charge of thermal management.
56 .set_mode: set the mode (enabled/disabled) of the thermal zone.
57 .get_trip_type: get the type of certain trip point.
58 .get_trip_temp: get the temperature above which the certain trip point
59 will be fired.
60 .set_emul_temp: set the emulation temperature which helps in debugging
61 different threshold temperature points.
62 tzp: thermal zone platform parameters.
63 passive_delay: number of milliseconds to wait between polls when
64 performing passive cooling.
65 polling_delay: number of milliseconds to wait between polls when checking
66 whether trip points have been crossed (0 for interrupt driven systems).
67
68
69 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
70
71 This interface function removes the thermal zone device.
72 It deletes the corresponding entry form /sys/class/thermal folder and
73 unbind all the thermal cooling devices it uses.
74
75 1.2 thermal cooling device interface
76 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
77 void *devdata, struct thermal_cooling_device_ops *)
78
79 This interface function adds a new thermal cooling device (fan/processor/...)
80 to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
81 to all the thermal zone devices register at the same time.
82 name: the cooling device name.
83 devdata: device private data.
84 ops: thermal cooling devices call-backs.
85 .get_max_state: get the Maximum throttle state of the cooling device.
86 .get_cur_state: get the Current throttle state of the cooling device.
87 .set_cur_state: set the Current throttle state of the cooling device.
88
89 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
90
91 This interface function remove the thermal cooling device.
92 It deletes the corresponding entry form /sys/class/thermal folder and
93 unbind itself from all the thermal zone devices using it.
94
95 1.3 interface for binding a thermal zone device with a thermal cooling device
96 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
97 int trip, struct thermal_cooling_device *cdev,
98 unsigned long upper, unsigned long lower, unsigned int weight);
99
100 This interface function bind a thermal cooling device to the certain trip
101 point of a thermal zone device.
102 This function is usually called in the thermal zone device .bind callback.
103 tz: the thermal zone device
104 cdev: thermal cooling device
105 trip: indicates which trip point the cooling devices is associated with
106 in this thermal zone.
107 upper:the Maximum cooling state for this trip point.
108 THERMAL_NO_LIMIT means no upper limit,
109 and the cooling device can be in max_state.
110 lower:the Minimum cooling state can be used for this trip point.
111 THERMAL_NO_LIMIT means no lower limit,
112 and the cooling device can be in cooling state 0.
113 weight: the influence of this cooling device in this thermal
114 zone. See 1.4.1 below for more information.
115
116 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
117 int trip, struct thermal_cooling_device *cdev);
118
119 This interface function unbind a thermal cooling device from the certain
120 trip point of a thermal zone device. This function is usually called in
121 the thermal zone device .unbind callback.
122 tz: the thermal zone device
123 cdev: thermal cooling device
124 trip: indicates which trip point the cooling devices is associated with
125 in this thermal zone.
126
127 1.4 Thermal Zone Parameters
128 1.4.1 struct thermal_bind_params
129 This structure defines the following parameters that are used to bind
130 a zone with a cooling device for a particular trip point.
131 .cdev: The cooling device pointer
132 .weight: The 'influence' of a particular cooling device on this
133 zone. This is relative to the rest of the cooling
134 devices. For example, if all cooling devices have a
135 weight of 1, then they all contribute the same. You can
136 use percentages if you want, but it's not mandatory. A
137 weight of 0 means that this cooling device doesn't
138 contribute to the cooling of this zone unless all cooling
139 devices have a weight of 0. If all weights are 0, then
140 they all contribute the same.
141 .trip_mask:This is a bit mask that gives the binding relation between
142 this thermal zone and cdev, for a particular trip point.
143 If nth bit is set, then the cdev and thermal zone are bound
144 for trip point n.
145 .limits: This is an array of cooling state limits. Must have exactly
146 2 * thermal_zone.number_of_trip_points. It is an array consisting
147 of tuples <lower-state upper-state> of state limits. Each trip
148 will be associated with one state limit tuple when binding.
149 A NULL pointer means <THERMAL_NO_LIMITS THERMAL_NO_LIMITS>
150 on all trips. These limits are used when binding a cdev to a
151 trip point.
152 .match: This call back returns success(0) if the 'tz and cdev' need to
153 be bound, as per platform data.
154 1.4.2 struct thermal_zone_params
155 This structure defines the platform level parameters for a thermal zone.
156 This data, for each thermal zone should come from the platform layer.
157 This is an optional feature where some platforms can choose not to
158 provide this data.
159 .governor_name: Name of the thermal governor used for this zone
160 .no_hwmon: a boolean to indicate if the thermal to hwmon sysfs interface
161 is required. when no_hwmon == false, a hwmon sysfs interface
162 will be created. when no_hwmon == true, nothing will be done.
163 In case the thermal_zone_params is NULL, the hwmon interface
164 will be created (for backward compatibility).
165 .num_tbps: Number of thermal_bind_params entries for this zone
166 .tbp: thermal_bind_params entries
167
168 2. sysfs attributes structure
169
170 RO read only value
171 RW read/write value
172
173 Thermal sysfs attributes will be represented under /sys/class/thermal.
174 Hwmon sysfs I/F extension is also available under /sys/class/hwmon
175 if hwmon is compiled in or built as a module.
176
177 Thermal zone device sys I/F, created once it's registered:
178 /sys/class/thermal/thermal_zone[0-*]:
179 |---type: Type of the thermal zone
180 |---temp: Current temperature
181 |---mode: Working mode of the thermal zone
182 |---policy: Thermal governor used for this zone
183 |---trip_point_[0-*]_temp: Trip point temperature
184 |---trip_point_[0-*]_type: Trip point type
185 |---trip_point_[0-*]_hyst: Hysteresis value for this trip point
186 |---emul_temp: Emulated temperature set node
187 |---sustainable_power: Sustainable dissipatable power
188 |---k_po: Proportional term during temperature overshoot
189 |---k_pu: Proportional term during temperature undershoot
190 |---k_i: PID's integral term in the power allocator gov
191 |---k_d: PID's derivative term in the power allocator
192 |---integral_cutoff: Offset above which errors are accumulated
193 |---slope: Slope constant applied as linear extrapolation
194 |---offset: Offset constant applied as linear extrapolation
195
196 Thermal cooling device sys I/F, created once it's registered:
197 /sys/class/thermal/cooling_device[0-*]:
198 |---type: Type of the cooling device(processor/fan/...)
199 |---max_state: Maximum cooling state of the cooling device
200 |---cur_state: Current cooling state of the cooling device
201
202
203 Then next two dynamic attributes are created/removed in pairs. They represent
204 the relationship between a thermal zone and its associated cooling device.
205 They are created/removed for each successful execution of
206 thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
207
208 /sys/class/thermal/thermal_zone[0-*]:
209 |---cdev[0-*]: [0-*]th cooling device in current thermal zone
210 |---cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with
211 |---cdev[0-*]_weight: Influence of the cooling device in
212 this thermal zone
213
214 Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
215 the generic thermal driver also creates a hwmon sysfs I/F for each _type_
216 of thermal zone device. E.g. the generic thermal driver registers one hwmon
217 class device and build the associated hwmon sysfs I/F for all the registered
218 ACPI thermal zones.
219
220 /sys/class/hwmon/hwmon[0-*]:
221 |---name: The type of the thermal zone devices
222 |---temp[1-*]_input: The current temperature of thermal zone [1-*]
223 |---temp[1-*]_critical: The critical trip point of thermal zone [1-*]
224
225 Please read Documentation/hwmon/sysfs-interface for additional information.
226
227 ***************************
228 * Thermal zone attributes *
229 ***************************
230
231 type
232 Strings which represent the thermal zone type.
233 This is given by thermal zone driver as part of registration.
234 E.g: "acpitz" indicates it's an ACPI thermal device.
235 In order to keep it consistent with hwmon sys attribute; this should
236 be a short, lowercase string, not containing spaces nor dashes.
237 RO, Required
238
239 temp
240 Current temperature as reported by thermal zone (sensor).
241 Unit: millidegree Celsius
242 RO, Required
243
244 mode
245 One of the predefined values in [enabled, disabled].
246 This file gives information about the algorithm that is currently
247 managing the thermal zone. It can be either default kernel based
248 algorithm or user space application.
249 enabled = enable Kernel Thermal management.
250 disabled = Preventing kernel thermal zone driver actions upon
251 trip points so that user application can take full
252 charge of the thermal management.
253 RW, Optional
254
255 policy
256 One of the various thermal governors used for a particular zone.
257 RW, Required
258
259 trip_point_[0-*]_temp
260 The temperature above which trip point will be fired.
261 Unit: millidegree Celsius
262 RO, Optional
263
264 trip_point_[0-*]_type
265 Strings which indicate the type of the trip point.
266 E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
267 thermal zone.
268 RO, Optional
269
270 trip_point_[0-*]_hyst
271 The hysteresis value for a trip point, represented as an integer
272 Unit: Celsius
273 RW, Optional
274
275 cdev[0-*]
276 Sysfs link to the thermal cooling device node where the sys I/F
277 for cooling device throttling control represents.
278 RO, Optional
279
280 cdev[0-*]_trip_point
281 The trip point with which cdev[0-*] is associated in this thermal
282 zone; -1 means the cooling device is not associated with any trip
283 point.
284 RO, Optional
285
286 cdev[0-*]_weight
287 The influence of cdev[0-*] in this thermal zone. This value
288 is relative to the rest of cooling devices in the thermal
289 zone. For example, if a cooling device has a weight double
290 than that of other, it's twice as effective in cooling the
291 thermal zone.
292 RW, Optional
293
294 passive
295 Attribute is only present for zones in which the passive cooling
296 policy is not supported by native thermal driver. Default is zero
297 and can be set to a temperature (in millidegrees) to enable a
298 passive trip point for the zone. Activation is done by polling with
299 an interval of 1 second.
300 Unit: millidegrees Celsius
301 Valid values: 0 (disabled) or greater than 1000
302 RW, Optional
303
304 emul_temp
305 Interface to set the emulated temperature method in thermal zone
306 (sensor). After setting this temperature, the thermal zone may pass
307 this temperature to platform emulation function if registered or
308 cache it locally. This is useful in debugging different temperature
309 threshold and its associated cooling action. This is write only node
310 and writing 0 on this node should disable emulation.
311 Unit: millidegree Celsius
312 WO, Optional
313
314 WARNING: Be careful while enabling this option on production systems,
315 because userland can easily disable the thermal policy by simply
316 flooding this sysfs node with low temperature values.
317
318 sustainable_power
319 An estimate of the sustained power that can be dissipated by
320 the thermal zone. Used by the power allocator governor. For
321 more information see Documentation/thermal/power_allocator.txt
322 Unit: milliwatts
323 RW, Optional
324
325 k_po
326 The proportional term of the power allocator governor's PID
327 controller during temperature overshoot. Temperature overshoot
328 is when the current temperature is above the "desired
329 temperature" trip point. For more information see
330 Documentation/thermal/power_allocator.txt
331 RW, Optional
332
333 k_pu
334 The proportional term of the power allocator governor's PID
335 controller during temperature undershoot. Temperature undershoot
336 is when the current temperature is below the "desired
337 temperature" trip point. For more information see
338 Documentation/thermal/power_allocator.txt
339 RW, Optional
340
341 k_i
342 The integral term of the power allocator governor's PID
343 controller. This term allows the PID controller to compensate
344 for long term drift. For more information see
345 Documentation/thermal/power_allocator.txt
346 RW, Optional
347
348 k_d
349 The derivative term of the power allocator governor's PID
350 controller. For more information see
351 Documentation/thermal/power_allocator.txt
352 RW, Optional
353
354 integral_cutoff
355 Temperature offset from the desired temperature trip point
356 above which the integral term of the power allocator
357 governor's PID controller starts accumulating errors. For
358 example, if integral_cutoff is 0, then the integral term only
359 accumulates error when temperature is above the desired
360 temperature trip point. For more information see
361 Documentation/thermal/power_allocator.txt
362 RW, Optional
363
364 slope
365 The slope constant used in a linear extrapolation model
366 to determine a hotspot temperature based off the sensor's
367 raw readings. It is up to the device driver to determine
368 the usage of these values.
369 RW, Optional
370
371 offset
372 The offset constant used in a linear extrapolation model
373 to determine a hotspot temperature based off the sensor's
374 raw readings. It is up to the device driver to determine
375 the usage of these values.
376 RW, Optional
377
378 *****************************
379 * Cooling device attributes *
380 *****************************
381
382 type
383 String which represents the type of device, e.g:
384 - for generic ACPI: should be "Fan", "Processor" or "LCD"
385 - for memory controller device on intel_menlow platform:
386 should be "Memory controller".
387 RO, Required
388
389 max_state
390 The maximum permissible cooling state of this cooling device.
391 RO, Required
392
393 cur_state
394 The current cooling state of this cooling device.
395 The value can any integer numbers between 0 and max_state:
396 - cur_state == 0 means no cooling
397 - cur_state == max_state means the maximum cooling.
398 RW, Required
399
400 3. A simple implementation
401
402 ACPI thermal zone may support multiple trip points like critical, hot,
403 passive, active. If an ACPI thermal zone supports critical, passive,
404 active[0] and active[1] at the same time, it may register itself as a
405 thermal_zone_device (thermal_zone1) with 4 trip points in all.
406 It has one processor and one fan, which are both registered as
407 thermal_cooling_device. Both are considered to have the same
408 effectiveness in cooling the thermal zone.
409
410 If the processor is listed in _PSL method, and the fan is listed in _AL0
411 method, the sys I/F structure will be built like this:
412
413 /sys/class/thermal:
414
415 |thermal_zone1:
416 |---type: acpitz
417 |---temp: 37000
418 |---mode: enabled
419 |---policy: step_wise
420 |---trip_point_0_temp: 100000
421 |---trip_point_0_type: critical
422 |---trip_point_1_temp: 80000
423 |---trip_point_1_type: passive
424 |---trip_point_2_temp: 70000
425 |---trip_point_2_type: active0
426 |---trip_point_3_temp: 60000
427 |---trip_point_3_type: active1
428 |---cdev0: --->/sys/class/thermal/cooling_device0
429 |---cdev0_trip_point: 1 /* cdev0 can be used for passive */
430 |---cdev0_weight: 1024
431 |---cdev1: --->/sys/class/thermal/cooling_device3
432 |---cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/
433 |---cdev1_weight: 1024
434
435 |cooling_device0:
436 |---type: Processor
437 |---max_state: 8
438 |---cur_state: 0
439
440 |cooling_device3:
441 |---type: Fan
442 |---max_state: 2
443 |---cur_state: 0
444
445 /sys/class/hwmon:
446
447 |hwmon0:
448 |---name: acpitz
449 |---temp1_input: 37000
450 |---temp1_crit: 100000
451
452 4. Event Notification
453
454 The framework includes a simple notification mechanism, in the form of a
455 netlink event. Netlink socket initialization is done during the _init_
456 of the framework. Drivers which intend to use the notification mechanism
457 just need to call thermal_generate_netlink_event() with two arguments viz
458 (originator, event). The originator is a pointer to struct thermal_zone_device
459 from where the event has been originated. An integer which represents the
460 thermal zone device will be used in the message to identify the zone. The
461 event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
462 THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
463 crosses any of the configured thresholds.
464
465 5. Export Symbol APIs:
466
467 5.1: get_tz_trend:
468 This function returns the trend of a thermal zone, i.e the rate of change
469 of temperature of the thermal zone. Ideally, the thermal sensor drivers
470 are supposed to implement the callback. If they don't, the thermal
471 framework calculated the trend by comparing the previous and the current
472 temperature values.
473
474 5.2:get_thermal_instance:
475 This function returns the thermal_instance corresponding to a given
476 {thermal_zone, cooling_device, trip_point} combination. Returns NULL
477 if such an instance does not exist.
478
479 5.3:thermal_notify_framework:
480 This function handles the trip events from sensor drivers. It starts
481 throttling the cooling devices according to the policy configured.
482 For CRITICAL and HOT trip points, this notifies the respective drivers,
483 and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
484 The throttling policy is based on the configured platform data; if no
485 platform data is provided, this uses the step_wise throttling policy.
486
487 5.4:thermal_cdev_update:
488 This function serves as an arbitrator to set the state of a cooling
489 device. It sets the cooling device to the deepest cooling state if
490 possible.
This page took 0.068002 seconds and 5 git commands to generate.