Merge tag 'sound-3.6' of git://git.kernel.org/pub/scm/linux/kernel/git/tiwai/sound
[deliverable/linux.git] / drivers / md / Kconfig
1 #
2 # Block device driver configuration
3 #
4
5 menuconfig MD
6 bool "Multiple devices driver support (RAID and LVM)"
7 depends on BLOCK
8 help
9 Support multiple physical spindles through a single logical device.
10 Required for RAID and logical volume management.
11
12 if MD
13
14 config BLK_DEV_MD
15 tristate "RAID support"
16 ---help---
17 This driver lets you combine several hard disk partitions into one
18 logical block device. This can be used to simply append one
19 partition to another one or to combine several redundant hard disks
20 into a RAID1/4/5 device so as to provide protection against hard
21 disk failures. This is called "Software RAID" since the combining of
22 the partitions is done by the kernel. "Hardware RAID" means that the
23 combining is done by a dedicated controller; if you have such a
24 controller, you do not need to say Y here.
25
26 More information about Software RAID on Linux is contained in the
27 Software RAID mini-HOWTO, available from
28 <http://www.tldp.org/docs.html#howto>. There you will also learn
29 where to get the supporting user space utilities raidtools.
30
31 If unsure, say N.
32
33 config MD_AUTODETECT
34 bool "Autodetect RAID arrays during kernel boot"
35 depends on BLK_DEV_MD=y
36 default y
37 ---help---
38 If you say Y here, then the kernel will try to autodetect raid
39 arrays as part of its boot process.
40
41 If you don't use raid and say Y, this autodetection can cause
42 a several-second delay in the boot time due to various
43 synchronisation steps that are part of this step.
44
45 If unsure, say Y.
46
47 config MD_LINEAR
48 tristate "Linear (append) mode"
49 depends on BLK_DEV_MD
50 ---help---
51 If you say Y here, then your multiple devices driver will be able to
52 use the so-called linear mode, i.e. it will combine the hard disk
53 partitions by simply appending one to the other.
54
55 To compile this as a module, choose M here: the module
56 will be called linear.
57
58 If unsure, say Y.
59
60 config MD_RAID0
61 tristate "RAID-0 (striping) mode"
62 depends on BLK_DEV_MD
63 ---help---
64 If you say Y here, then your multiple devices driver will be able to
65 use the so-called raid0 mode, i.e. it will combine the hard disk
66 partitions into one logical device in such a fashion as to fill them
67 up evenly, one chunk here and one chunk there. This will increase
68 the throughput rate if the partitions reside on distinct disks.
69
70 Information about Software RAID on Linux is contained in the
71 Software-RAID mini-HOWTO, available from
72 <http://www.tldp.org/docs.html#howto>. There you will also
73 learn where to get the supporting user space utilities raidtools.
74
75 To compile this as a module, choose M here: the module
76 will be called raid0.
77
78 If unsure, say Y.
79
80 config MD_RAID1
81 tristate "RAID-1 (mirroring) mode"
82 depends on BLK_DEV_MD
83 ---help---
84 A RAID-1 set consists of several disk drives which are exact copies
85 of each other. In the event of a mirror failure, the RAID driver
86 will continue to use the operational mirrors in the set, providing
87 an error free MD (multiple device) to the higher levels of the
88 kernel. In a set with N drives, the available space is the capacity
89 of a single drive, and the set protects against a failure of (N - 1)
90 drives.
91
92 Information about Software RAID on Linux is contained in the
93 Software-RAID mini-HOWTO, available from
94 <http://www.tldp.org/docs.html#howto>. There you will also
95 learn where to get the supporting user space utilities raidtools.
96
97 If you want to use such a RAID-1 set, say Y. To compile this code
98 as a module, choose M here: the module will be called raid1.
99
100 If unsure, say Y.
101
102 config MD_RAID10
103 tristate "RAID-10 (mirrored striping) mode"
104 depends on BLK_DEV_MD
105 ---help---
106 RAID-10 provides a combination of striping (RAID-0) and
107 mirroring (RAID-1) with easier configuration and more flexible
108 layout.
109 Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
110 be the same size (or at least, only as much as the smallest device
111 will be used).
112 RAID-10 provides a variety of layouts that provide different levels
113 of redundancy and performance.
114
115 RAID-10 requires mdadm-1.7.0 or later, available at:
116
117 ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
118
119 If unsure, say Y.
120
121 config MD_RAID456
122 tristate "RAID-4/RAID-5/RAID-6 mode"
123 depends on BLK_DEV_MD
124 select RAID6_PQ
125 select ASYNC_MEMCPY
126 select ASYNC_XOR
127 select ASYNC_PQ
128 select ASYNC_RAID6_RECOV
129 ---help---
130 A RAID-5 set of N drives with a capacity of C MB per drive provides
131 the capacity of C * (N - 1) MB, and protects against a failure
132 of a single drive. For a given sector (row) number, (N - 1) drives
133 contain data sectors, and one drive contains the parity protection.
134 For a RAID-4 set, the parity blocks are present on a single drive,
135 while a RAID-5 set distributes the parity across the drives in one
136 of the available parity distribution methods.
137
138 A RAID-6 set of N drives with a capacity of C MB per drive
139 provides the capacity of C * (N - 2) MB, and protects
140 against a failure of any two drives. For a given sector
141 (row) number, (N - 2) drives contain data sectors, and two
142 drives contains two independent redundancy syndromes. Like
143 RAID-5, RAID-6 distributes the syndromes across the drives
144 in one of the available parity distribution methods.
145
146 Information about Software RAID on Linux is contained in the
147 Software-RAID mini-HOWTO, available from
148 <http://www.tldp.org/docs.html#howto>. There you will also
149 learn where to get the supporting user space utilities raidtools.
150
151 If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y. To
152 compile this code as a module, choose M here: the module
153 will be called raid456.
154
155 If unsure, say Y.
156
157 config MULTICORE_RAID456
158 bool "RAID-4/RAID-5/RAID-6 Multicore processing (EXPERIMENTAL)"
159 depends on MD_RAID456
160 depends on SMP
161 depends on EXPERIMENTAL
162 ---help---
163 Enable the raid456 module to dispatch per-stripe raid operations to a
164 thread pool.
165
166 If unsure, say N.
167
168 config MD_MULTIPATH
169 tristate "Multipath I/O support"
170 depends on BLK_DEV_MD
171 help
172 MD_MULTIPATH provides a simple multi-path personality for use
173 the MD framework. It is not under active development. New
174 projects should consider using DM_MULTIPATH which has more
175 features and more testing.
176
177 If unsure, say N.
178
179 config MD_FAULTY
180 tristate "Faulty test module for MD"
181 depends on BLK_DEV_MD
182 help
183 The "faulty" module allows for a block device that occasionally returns
184 read or write errors. It is useful for testing.
185
186 In unsure, say N.
187
188 config BLK_DEV_DM
189 tristate "Device mapper support"
190 ---help---
191 Device-mapper is a low level volume manager. It works by allowing
192 people to specify mappings for ranges of logical sectors. Various
193 mapping types are available, in addition people may write their own
194 modules containing custom mappings if they wish.
195
196 Higher level volume managers such as LVM2 use this driver.
197
198 To compile this as a module, choose M here: the module will be
199 called dm-mod.
200
201 If unsure, say N.
202
203 config DM_DEBUG
204 boolean "Device mapper debugging support"
205 depends on BLK_DEV_DM
206 ---help---
207 Enable this for messages that may help debug device-mapper problems.
208
209 If unsure, say N.
210
211 config DM_BUFIO
212 tristate
213 depends on BLK_DEV_DM && EXPERIMENTAL
214 ---help---
215 This interface allows you to do buffered I/O on a device and acts
216 as a cache, holding recently-read blocks in memory and performing
217 delayed writes.
218
219 source "drivers/md/persistent-data/Kconfig"
220
221 config DM_CRYPT
222 tristate "Crypt target support"
223 depends on BLK_DEV_DM
224 select CRYPTO
225 select CRYPTO_CBC
226 ---help---
227 This device-mapper target allows you to create a device that
228 transparently encrypts the data on it. You'll need to activate
229 the ciphers you're going to use in the cryptoapi configuration.
230
231 Information on how to use dm-crypt can be found on
232
233 <http://www.saout.de/misc/dm-crypt/>
234
235 To compile this code as a module, choose M here: the module will
236 be called dm-crypt.
237
238 If unsure, say N.
239
240 config DM_SNAPSHOT
241 tristate "Snapshot target"
242 depends on BLK_DEV_DM
243 ---help---
244 Allow volume managers to take writable snapshots of a device.
245
246 config DM_THIN_PROVISIONING
247 tristate "Thin provisioning target (EXPERIMENTAL)"
248 depends on BLK_DEV_DM && EXPERIMENTAL
249 select DM_PERSISTENT_DATA
250 ---help---
251 Provides thin provisioning and snapshots that share a data store.
252
253 config DM_DEBUG_BLOCK_STACK_TRACING
254 boolean "Keep stack trace of thin provisioning block lock holders"
255 depends on STACKTRACE_SUPPORT && DM_THIN_PROVISIONING
256 select STACKTRACE
257 ---help---
258 Enable this for messages that may help debug problems with the
259 block manager locking used by thin provisioning.
260
261 If unsure, say N.
262
263 config DM_MIRROR
264 tristate "Mirror target"
265 depends on BLK_DEV_DM
266 ---help---
267 Allow volume managers to mirror logical volumes, also
268 needed for live data migration tools such as 'pvmove'.
269
270 config DM_RAID
271 tristate "RAID 1/4/5/6 target"
272 depends on BLK_DEV_DM
273 select MD_RAID1
274 select MD_RAID456
275 select BLK_DEV_MD
276 ---help---
277 A dm target that supports RAID1, RAID4, RAID5 and RAID6 mappings
278
279 A RAID-5 set of N drives with a capacity of C MB per drive provides
280 the capacity of C * (N - 1) MB, and protects against a failure
281 of a single drive. For a given sector (row) number, (N - 1) drives
282 contain data sectors, and one drive contains the parity protection.
283 For a RAID-4 set, the parity blocks are present on a single drive,
284 while a RAID-5 set distributes the parity across the drives in one
285 of the available parity distribution methods.
286
287 A RAID-6 set of N drives with a capacity of C MB per drive
288 provides the capacity of C * (N - 2) MB, and protects
289 against a failure of any two drives. For a given sector
290 (row) number, (N - 2) drives contain data sectors, and two
291 drives contains two independent redundancy syndromes. Like
292 RAID-5, RAID-6 distributes the syndromes across the drives
293 in one of the available parity distribution methods.
294
295 config DM_LOG_USERSPACE
296 tristate "Mirror userspace logging (EXPERIMENTAL)"
297 depends on DM_MIRROR && EXPERIMENTAL && NET
298 select CONNECTOR
299 ---help---
300 The userspace logging module provides a mechanism for
301 relaying the dm-dirty-log API to userspace. Log designs
302 which are more suited to userspace implementation (e.g.
303 shared storage logs) or experimental logs can be implemented
304 by leveraging this framework.
305
306 config DM_ZERO
307 tristate "Zero target"
308 depends on BLK_DEV_DM
309 ---help---
310 A target that discards writes, and returns all zeroes for
311 reads. Useful in some recovery situations.
312
313 config DM_MULTIPATH
314 tristate "Multipath target"
315 depends on BLK_DEV_DM
316 # nasty syntax but means make DM_MULTIPATH independent
317 # of SCSI_DH if the latter isn't defined but if
318 # it is, DM_MULTIPATH must depend on it. We get a build
319 # error if SCSI_DH=m and DM_MULTIPATH=y
320 depends on SCSI_DH || !SCSI_DH
321 ---help---
322 Allow volume managers to support multipath hardware.
323
324 config DM_MULTIPATH_QL
325 tristate "I/O Path Selector based on the number of in-flight I/Os"
326 depends on DM_MULTIPATH
327 ---help---
328 This path selector is a dynamic load balancer which selects
329 the path with the least number of in-flight I/Os.
330
331 If unsure, say N.
332
333 config DM_MULTIPATH_ST
334 tristate "I/O Path Selector based on the service time"
335 depends on DM_MULTIPATH
336 ---help---
337 This path selector is a dynamic load balancer which selects
338 the path expected to complete the incoming I/O in the shortest
339 time.
340
341 If unsure, say N.
342
343 config DM_DELAY
344 tristate "I/O delaying target (EXPERIMENTAL)"
345 depends on BLK_DEV_DM && EXPERIMENTAL
346 ---help---
347 A target that delays reads and/or writes and can send
348 them to different devices. Useful for testing.
349
350 If unsure, say N.
351
352 config DM_UEVENT
353 bool "DM uevents"
354 depends on BLK_DEV_DM
355 ---help---
356 Generate udev events for DM events.
357
358 config DM_FLAKEY
359 tristate "Flakey target (EXPERIMENTAL)"
360 depends on BLK_DEV_DM && EXPERIMENTAL
361 ---help---
362 A target that intermittently fails I/O for debugging purposes.
363
364 config DM_VERITY
365 tristate "Verity target support (EXPERIMENTAL)"
366 depends on BLK_DEV_DM && EXPERIMENTAL
367 select CRYPTO
368 select CRYPTO_HASH
369 select DM_BUFIO
370 ---help---
371 This device-mapper target creates a read-only device that
372 transparently validates the data on one underlying device against
373 a pre-generated tree of cryptographic checksums stored on a second
374 device.
375
376 You'll need to activate the digests you're going to use in the
377 cryptoapi configuration.
378
379 To compile this code as a module, choose M here: the module will
380 be called dm-verity.
381
382 If unsure, say N.
383
384 endif # MD
This page took 0.040708 seconds and 5 git commands to generate.