1 /*
2 * Copyright (C) 2011 Samsung Electronics Co., Ltd.
3 * MyungJoo Ham <myungjoo.ham@samsung.com>
4 *
5 * This driver enables to monitor battery health and control charger
6 * during suspend-to-mem.
7 * Charger manager depends on other devices. register this later than
8 * the depending devices.
9 *
10 * This program is free software; you can redistribute it and/or modify
11 * it under the terms of the GNU General Public License version 2 as
12 * published by the Free Software Foundation.
13 **/
14
15 #include <linux/io.h>
16 #include <linux/module.h>
17 #include <linux/irq.h>
18 #include <linux/interrupt.h>
19 #include <linux/rtc.h>
20 #include <linux/slab.h>
21 #include <linux/workqueue.h>
22 #include <linux/platform_device.h>
23 #include <linux/power/charger-manager.h>
24 #include <linux/regulator/consumer.h>
25
26 static const char * const default_event_names[] = {
27 [CM_EVENT_UNKNOWN] = "Unknown",
28 [CM_EVENT_BATT_FULL] = "Battery Full",
29 [CM_EVENT_BATT_IN] = "Battery Inserted",
30 [CM_EVENT_BATT_OUT] = "Battery Pulled Out",
31 [CM_EVENT_EXT_PWR_IN_OUT] = "External Power Attach/Detach",
32 [CM_EVENT_CHG_START_STOP] = "Charging Start/Stop",
33 [CM_EVENT_OTHERS] = "Other battery events"
34 };
35
36 /*
37 * Regard CM_JIFFIES_SMALL jiffies is small enough to ignore for
38 * delayed works so that we can run delayed works with CM_JIFFIES_SMALL
39 * without any delays.
40 */
41 #define CM_JIFFIES_SMALL (2)
42
43 /* If y is valid (> 0) and smaller than x, do x = y */
44 #define CM_MIN_VALID(x, y) x = (((y > 0) && ((x) > (y))) ? (y) : (x))
45
46 /*
47 * Regard CM_RTC_SMALL (sec) is small enough to ignore error in invoking
48 * rtc alarm. It should be 2 or larger
49 */
50 #define CM_RTC_SMALL (2)
51
52 #define UEVENT_BUF_SIZE 32
53
54 static LIST_HEAD(cm_list);
55 static DEFINE_MUTEX(cm_list_mtx);
56
57 /* About in-suspend (suspend-again) monitoring */
58 static struct rtc_device *rtc_dev;
59 /*
60 * Backup RTC alarm
61 * Save the wakeup alarm before entering suspend-to-RAM
62 */
63 static struct rtc_wkalrm rtc_wkalarm_save;
64 /* Backup RTC alarm time in terms of seconds since 01-01-1970 00:00:00 */
65 static unsigned long rtc_wkalarm_save_time;
66 static bool cm_suspended;
67 static bool cm_rtc_set;
68 static unsigned long cm_suspend_duration_ms;
69
70 /* About normal (not suspended) monitoring */
71 static unsigned long polling_jiffy = ULONG_MAX; /* ULONG_MAX: no polling */
72 static unsigned long next_polling; /* Next appointed polling time */
73 static struct workqueue_struct *cm_wq; /* init at driver add */
74 static struct delayed_work cm_monitor_work; /* init at driver add */
75
76 /* Global charger-manager description */
77 static struct charger_global_desc *g_desc; /* init with setup_charger_manager */
78
79 /**
80 * is_batt_present - See if the battery presents in place.
81 * @cm: the Charger Manager representing the battery.
82 */
83 static bool is_batt_present(struct charger_manager *cm)
84 {
85 union power_supply_propval val;
86 bool present = false;
87 int i, ret;
88
89 switch (cm->desc->battery_present) {
90 case CM_BATTERY_PRESENT:
91 present = true;
92 break;
93 case CM_NO_BATTERY:
94 break;
95 case CM_FUEL_GAUGE:
96 ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
97 POWER_SUPPLY_PROP_PRESENT, &val);
98 if (ret == 0 && val.intval)
99 present = true;
100 break;
101 case CM_CHARGER_STAT:
102 for (i = 0; cm->charger_stat[i]; i++) {
103 ret = cm->charger_stat[i]->get_property(
104 cm->charger_stat[i],
105 POWER_SUPPLY_PROP_PRESENT, &val);
106 if (ret == 0 && val.intval) {
107 present = true;
108 break;
109 }
110 }
111 break;
112 }
113
114 return present;
115 }
116
117 /**
118 * is_ext_pwr_online - See if an external power source is attached to charge
119 * @cm: the Charger Manager representing the battery.
120 *
121 * Returns true if at least one of the chargers of the battery has an external
122 * power source attached to charge the battery regardless of whether it is
123 * actually charging or not.
124 */
125 static bool is_ext_pwr_online(struct charger_manager *cm)
126 {
127 union power_supply_propval val;
128 bool online = false;
129 int i, ret;
130
131 /* If at least one of them has one, it's yes. */
132 for (i = 0; cm->charger_stat[i]; i++) {
133 ret = cm->charger_stat[i]->get_property(
134 cm->charger_stat[i],
135 POWER_SUPPLY_PROP_ONLINE, &val);
136 if (ret == 0 && val.intval) {
137 online = true;
138 break;
139 }
140 }
141
142 return online;
143 }
144
145 /**
146 * get_batt_uV - Get the voltage level of the battery
147 * @cm: the Charger Manager representing the battery.
148 * @uV: the voltage level returned.
149 *
150 * Returns 0 if there is no error.
151 * Returns a negative value on error.
152 */
153 static int get_batt_uV(struct charger_manager *cm, int *uV)
154 {
155 union power_supply_propval val;
156 int ret;
157
158 if (!cm->fuel_gauge)
159 return -ENODEV;
160
161 ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
162 POWER_SUPPLY_PROP_VOLTAGE_NOW, &val);
163 if (ret)
164 return ret;
165
166 *uV = val.intval;
167 return 0;
168 }
169
170 /**
171 * is_charging - Returns true if the battery is being charged.
172 * @cm: the Charger Manager representing the battery.
173 */
174 static bool is_charging(struct charger_manager *cm)
175 {
176 int i, ret;
177 bool charging = false;
178 union power_supply_propval val;
179
180 /* If there is no battery, it cannot be charged */
181 if (!is_batt_present(cm))
182 return false;
183
184 /* If at least one of the charger is charging, return yes */
185 for (i = 0; cm->charger_stat[i]; i++) {
186 /* 1. The charger sholuld not be DISABLED */
187 if (cm->emergency_stop)
188 continue;
189 if (!cm->charger_enabled)
190 continue;
191
192 /* 2. The charger should be online (ext-power) */
193 ret = cm->charger_stat[i]->get_property(
194 cm->charger_stat[i],
195 POWER_SUPPLY_PROP_ONLINE, &val);
196 if (ret) {
197 dev_warn(cm->dev, "Cannot read ONLINE value from %s.\n",
198 cm->desc->psy_charger_stat[i]);
199 continue;
200 }
201 if (val.intval == 0)
202 continue;
203
204 /*
205 * 3. The charger should not be FULL, DISCHARGING,
206 * or NOT_CHARGING.
207 */
208 ret = cm->charger_stat[i]->get_property(
209 cm->charger_stat[i],
210 POWER_SUPPLY_PROP_STATUS, &val);
211 if (ret) {
212 dev_warn(cm->dev, "Cannot read STATUS value from %s.\n",
213 cm->desc->psy_charger_stat[i]);
214 continue;
215 }
216 if (val.intval == POWER_SUPPLY_STATUS_FULL ||
217 val.intval == POWER_SUPPLY_STATUS_DISCHARGING ||
218 val.intval == POWER_SUPPLY_STATUS_NOT_CHARGING)
219 continue;
220
221 /* Then, this is charging. */
222 charging = true;
223 break;
224 }
225
226 return charging;
227 }
228
229 /**
230 * is_polling_required - Return true if need to continue polling for this CM.
231 * @cm: the Charger Manager representing the battery.
232 */
233 static bool is_polling_required(struct charger_manager *cm)
234 {
235 switch (cm->desc->polling_mode) {
236 case CM_POLL_DISABLE:
237 return false;
238 case CM_POLL_ALWAYS:
239 return true;
240 case CM_POLL_EXTERNAL_POWER_ONLY:
241 return is_ext_pwr_online(cm);
242 case CM_POLL_CHARGING_ONLY:
243 return is_charging(cm);
244 default:
245 dev_warn(cm->dev, "Incorrect polling_mode (%d)\n",
246 cm->desc->polling_mode);
247 }
248
249 return false;
250 }
251
252 /**
253 * try_charger_enable - Enable/Disable chargers altogether
254 * @cm: the Charger Manager representing the battery.
255 * @enable: true: enable / false: disable
256 *
257 * Note that Charger Manager keeps the charger enabled regardless whether
258 * the charger is charging or not (because battery is full or no external
259 * power source exists) except when CM needs to disable chargers forcibly
260 * bacause of emergency causes; when the battery is overheated or too cold.
261 */
262 static int try_charger_enable(struct charger_manager *cm, bool enable)
263 {
264 int err = 0, i;
265 struct charger_desc *desc = cm->desc;
266
267 /* Ignore if it's redundent command */
268 if (enable == cm->charger_enabled)
269 return 0;
270
271 if (enable) {
272 if (cm->emergency_stop)
273 return -EAGAIN;
274 err = regulator_bulk_enable(desc->num_charger_regulators,
275 desc->charger_regulators);
276 } else {
277 /*
278 * Abnormal battery state - Stop charging forcibly,
279 * even if charger was enabled at the other places
280 */
281 err = regulator_bulk_disable(desc->num_charger_regulators,
282 desc->charger_regulators);
283
284 for (i = 0; i < desc->num_charger_regulators; i++) {
285 if (regulator_is_enabled(
286 desc->charger_regulators[i].consumer)) {
287 regulator_force_disable(
288 desc->charger_regulators[i].consumer);
289 dev_warn(cm->dev,
290 "Disable regulator(%s) forcibly.\n",
291 desc->charger_regulators[i].supply);
292 }
293 }
294 }
295
296 if (!err)
297 cm->charger_enabled = enable;
298
299 return err;
300 }
301
302 /**
303 * try_charger_restart - Restart charging.
304 * @cm: the Charger Manager representing the battery.
305 *
306 * Restart charging by turning off and on the charger.
307 */
308 static int try_charger_restart(struct charger_manager *cm)
309 {
310 int err;
311
312 if (cm->emergency_stop)
313 return -EAGAIN;
314
315 err = try_charger_enable(cm, false);
316 if (err)
317 return err;
318
319 return try_charger_enable(cm, true);
320 }
321
322 /**
323 * uevent_notify - Let users know something has changed.
324 * @cm: the Charger Manager representing the battery.
325 * @event: the event string.
326 *
327 * If @event is null, it implies that uevent_notify is called
328 * by resume function. When called in the resume function, cm_suspended
329 * should be already reset to false in order to let uevent_notify
330 * notify the recent event during the suspend to users. While
331 * suspended, uevent_notify does not notify users, but tracks
332 * events so that uevent_notify can notify users later after resumed.
333 */
334 static void uevent_notify(struct charger_manager *cm, const char *event)
335 {
336 static char env_str[UEVENT_BUF_SIZE + 1] = "";
337 static char env_str_save[UEVENT_BUF_SIZE + 1] = "";
338
339 if (cm_suspended) {
340 /* Nothing in suspended-event buffer */
341 if (env_str_save[0] == 0) {
342 if (!strncmp(env_str, event, UEVENT_BUF_SIZE))
343 return; /* status not changed */
344 strncpy(env_str_save, event, UEVENT_BUF_SIZE);
345 return;
346 }
347
348 if (!strncmp(env_str_save, event, UEVENT_BUF_SIZE))
349 return; /* Duplicated. */
350 strncpy(env_str_save, event, UEVENT_BUF_SIZE);
351 return;
352 }
353
354 if (event == NULL) {
355 /* No messages pending */
356 if (!env_str_save[0])
357 return;
358
359 strncpy(env_str, env_str_save, UEVENT_BUF_SIZE);
360 kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE);
361 env_str_save[0] = 0;
362
363 return;
364 }
365
366 /* status not changed */
367 if (!strncmp(env_str, event, UEVENT_BUF_SIZE))
368 return;
369
370 /* save the status and notify the update */
371 strncpy(env_str, event, UEVENT_BUF_SIZE);
372 kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE);
373
374 dev_info(cm->dev, event);
375 }
376
377 /**
378 * fullbatt_vchk - Check voltage drop some times after "FULL" event.
379 * @work: the work_struct appointing the function
380 *
381 * If a user has designated "fullbatt_vchkdrop_ms/uV" values with
382 * charger_desc, Charger Manager checks voltage drop after the battery
383 * "FULL" event. It checks whether the voltage has dropped more than
384 * fullbatt_vchkdrop_uV by calling this function after fullbatt_vchkrop_ms.
385 */
386 static void fullbatt_vchk(struct work_struct *work)
387 {
388 struct delayed_work *dwork = to_delayed_work(work);
389 struct charger_manager *cm = container_of(dwork,
390 struct charger_manager, fullbatt_vchk_work);
391 struct charger_desc *desc = cm->desc;
392 int batt_uV, err, diff;
393
394 /* remove the appointment for fullbatt_vchk */
395 cm->fullbatt_vchk_jiffies_at = 0;
396
397 if (!desc->fullbatt_vchkdrop_uV || !desc->fullbatt_vchkdrop_ms)
398 return;
399
400 err = get_batt_uV(cm, &batt_uV);
401 if (err) {
402 dev_err(cm->dev, "%s: get_batt_uV error(%d).\n", __func__, err);
403 return;
404 }
405
406 diff = cm->fullbatt_vchk_uV;
407 diff -= batt_uV;
408
409 dev_dbg(cm->dev, "VBATT dropped %duV after full-batt.\n", diff);
410
411 if (diff > desc->fullbatt_vchkdrop_uV) {
412 try_charger_restart(cm);
413 uevent_notify(cm, "Recharge");
414 }
415 }
416
417 /**
418 * _cm_monitor - Monitor the temperature and return true for exceptions.
419 * @cm: the Charger Manager representing the battery.
420 *
421 * Returns true if there is an event to notify for the battery.
422 * (True if the status of "emergency_stop" changes)
423 */
424 static bool _cm_monitor(struct charger_manager *cm)
425 {
426 struct charger_desc *desc = cm->desc;
427 int temp = desc->temperature_out_of_range(&cm->last_temp_mC);
428
429 dev_dbg(cm->dev, "monitoring (%2.2d.%3.3dC)\n",
430 cm->last_temp_mC / 1000, cm->last_temp_mC % 1000);
431
432 /* It has been stopped or charging already */
433 if (!!temp == !!cm->emergency_stop)
434 return false;
435
436 if (temp) {
437 cm->emergency_stop = temp;
438 if (!try_charger_enable(cm, false)) {
439 if (temp > 0)
440 uevent_notify(cm, "OVERHEAT");
441 else
442 uevent_notify(cm, "COLD");
443 }
444 } else {
445 cm->emergency_stop = 0;
446 if (!try_charger_enable(cm, true))
447 uevent_notify(cm, "CHARGING");
448 }
449
450 return true;
451 }
452
453 /**
454 * cm_monitor - Monitor every battery.
455 *
456 * Returns true if there is an event to notify from any of the batteries.
457 * (True if the status of "emergency_stop" changes)
458 */
459 static bool cm_monitor(void)
460 {
461 bool stop = false;
462 struct charger_manager *cm;
463
464 mutex_lock(&cm_list_mtx);
465
466 list_for_each_entry(cm, &cm_list, entry) {
467 if (_cm_monitor(cm))
468 stop = true;
469 }
470
471 mutex_unlock(&cm_list_mtx);
472
473 return stop;
474 }
475
476 /**
477 * _setup_polling - Setup the next instance of polling.
478 * @work: work_struct of the function _setup_polling.
479 */
480 static void _setup_polling(struct work_struct *work)
481 {
482 unsigned long min = ULONG_MAX;
483 struct charger_manager *cm;
484 bool keep_polling = false;
485 unsigned long _next_polling;
486
487 mutex_lock(&cm_list_mtx);
488
489 list_for_each_entry(cm, &cm_list, entry) {
490 if (is_polling_required(cm) && cm->desc->polling_interval_ms) {
491 keep_polling = true;
492
493 if (min > cm->desc->polling_interval_ms)
494 min = cm->desc->polling_interval_ms;
495 }
496 }
497
498 polling_jiffy = msecs_to_jiffies(min);
499 if (polling_jiffy <= CM_JIFFIES_SMALL)
500 polling_jiffy = CM_JIFFIES_SMALL + 1;
501
502 if (!keep_polling)
503 polling_jiffy = ULONG_MAX;
504 if (polling_jiffy == ULONG_MAX)
505 goto out;
506
507 WARN(cm_wq == NULL, "charger-manager: workqueue not initialized"
508 ". try it later. %s\n", __func__);
509
510 _next_polling = jiffies + polling_jiffy;
511
512 if (!delayed_work_pending(&cm_monitor_work) ||
513 (delayed_work_pending(&cm_monitor_work) &&
514 time_after(next_polling, _next_polling))) {
515 cancel_delayed_work_sync(&cm_monitor_work);
516 next_polling = jiffies + polling_jiffy;
517 queue_delayed_work(cm_wq, &cm_monitor_work, polling_jiffy);
518 }
519
520 out:
521 mutex_unlock(&cm_list_mtx);
522 }
523 static DECLARE_WORK(setup_polling, _setup_polling);
524
525 /**
526 * cm_monitor_poller - The Monitor / Poller.
527 * @work: work_struct of the function cm_monitor_poller
528 *
529 * During non-suspended state, cm_monitor_poller is used to poll and monitor
530 * the batteries.
531 */
532 static void cm_monitor_poller(struct work_struct *work)
533 {
534 cm_monitor();
535 schedule_work(&setup_polling);
536 }
537
538 /**
539 * fullbatt_handler - Event handler for CM_EVENT_BATT_FULL
540 * @cm: the Charger Manager representing the battery.
541 */
542 static void fullbatt_handler(struct charger_manager *cm)
543 {
544 struct charger_desc *desc = cm->desc;
545
546 if (!desc->fullbatt_vchkdrop_uV || !desc->fullbatt_vchkdrop_ms)
547 goto out;
548
549 if (cm_suspended)
550 device_set_wakeup_capable(cm->dev, true);
551
552 if (delayed_work_pending(&cm->fullbatt_vchk_work))
553 cancel_delayed_work(&cm->fullbatt_vchk_work);
554 queue_delayed_work(cm_wq, &cm->fullbatt_vchk_work,
555 msecs_to_jiffies(desc->fullbatt_vchkdrop_ms));
556 cm->fullbatt_vchk_jiffies_at = jiffies + msecs_to_jiffies(
557 desc->fullbatt_vchkdrop_ms);
558
559 if (cm->fullbatt_vchk_jiffies_at == 0)
560 cm->fullbatt_vchk_jiffies_at = 1;
561
562 out:
563 dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged.\n");
564 uevent_notify(cm, default_event_names[CM_EVENT_BATT_FULL]);
565 }
566
567 /**
568 * battout_handler - Event handler for CM_EVENT_BATT_OUT
569 * @cm: the Charger Manager representing the battery.
570 */
571 static void battout_handler(struct charger_manager *cm)
572 {
573 if (cm_suspended)
574 device_set_wakeup_capable(cm->dev, true);
575
576 if (!is_batt_present(cm)) {
577 dev_emerg(cm->dev, "Battery Pulled Out!\n");
578 uevent_notify(cm, default_event_names[CM_EVENT_BATT_OUT]);
579 } else {
580 uevent_notify(cm, "Battery Reinserted?");
581 }
582 }
583
584 /**
585 * misc_event_handler - Handler for other evnets
586 * @cm: the Charger Manager representing the battery.
587 * @type: the Charger Manager representing the battery.
588 */
589 static void misc_event_handler(struct charger_manager *cm,
590 enum cm_event_types type)
591 {
592 if (cm_suspended)
593 device_set_wakeup_capable(cm->dev, true);
594
595 if (!delayed_work_pending(&cm_monitor_work) &&
596 is_polling_required(cm) && cm->desc->polling_interval_ms)
597 schedule_work(&setup_polling);
598 uevent_notify(cm, default_event_names[type]);
599 }
600
601 static int charger_get_property(struct power_supply *psy,
602 enum power_supply_property psp,
603 union power_supply_propval *val)
604 {
605 struct charger_manager *cm = container_of(psy,
606 struct charger_manager, charger_psy);
607 struct charger_desc *desc = cm->desc;
608 int ret = 0;
609 int uV;
610
611 switch (psp) {
612 case POWER_SUPPLY_PROP_STATUS:
613 if (is_charging(cm))
614 val->intval = POWER_SUPPLY_STATUS_CHARGING;
615 else if (is_ext_pwr_online(cm))
616 val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
617 else
618 val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
619 break;
620 case POWER_SUPPLY_PROP_HEALTH:
621 if (cm->emergency_stop > 0)
622 val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
623 else if (cm->emergency_stop < 0)
624 val->intval = POWER_SUPPLY_HEALTH_COLD;
625 else
626 val->intval = POWER_SUPPLY_HEALTH_GOOD;
627 break;
628 case POWER_SUPPLY_PROP_PRESENT:
629 if (is_batt_present(cm))
630 val->intval = 1;
631 else
632 val->intval = 0;
633 break;
634 case POWER_SUPPLY_PROP_VOLTAGE_NOW:
635 ret = get_batt_uV(cm, &val->intval);
636 break;
637 case POWER_SUPPLY_PROP_CURRENT_NOW:
638 ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
639 POWER_SUPPLY_PROP_CURRENT_NOW, val);
640 break;
641 case POWER_SUPPLY_PROP_TEMP:
642 /* in thenth of centigrade */
643 if (cm->last_temp_mC == INT_MIN)
644 desc->temperature_out_of_range(&cm->last_temp_mC);
645 val->intval = cm->last_temp_mC / 100;
646 if (!desc->measure_battery_temp)
647 ret = -ENODEV;
648 break;
649 case POWER_SUPPLY_PROP_TEMP_AMBIENT:
650 /* in thenth of centigrade */
651 if (cm->last_temp_mC == INT_MIN)
652 desc->temperature_out_of_range(&cm->last_temp_mC);
653 val->intval = cm->last_temp_mC / 100;
654 if (desc->measure_battery_temp)
655 ret = -ENODEV;
656 break;
657 case POWER_SUPPLY_PROP_CAPACITY:
658 if (!cm->fuel_gauge) {
659 ret = -ENODEV;
660 break;
661 }
662
663 if (!is_batt_present(cm)) {
664 /* There is no battery. Assume 100% */
665 val->intval = 100;
666 break;
667 }
668
669 ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
670 POWER_SUPPLY_PROP_CAPACITY, val);
671 if (ret)
672 break;
673
674 if (val->intval > 100) {
675 val->intval = 100;
676 break;
677 }
678 if (val->intval < 0)
679 val->intval = 0;
680
681 /* Do not adjust SOC when charging: voltage is overrated */
682 if (is_charging(cm))
683 break;
684
685 /*
686 * If the capacity value is inconsistent, calibrate it base on
687 * the battery voltage values and the thresholds given as desc
688 */
689 ret = get_batt_uV(cm, &uV);
690 if (ret) {
691 /* Voltage information not available. No calibration */
692 ret = 0;
693 break;
694 }
695
696 if (desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV &&
697 !is_charging(cm)) {
698 val->intval = 100;
699 break;
700 }
701
702 break;
703 case POWER_SUPPLY_PROP_ONLINE:
704 if (is_ext_pwr_online(cm))
705 val->intval = 1;
706 else
707 val->intval = 0;
708 break;
709 case POWER_SUPPLY_PROP_CHARGE_FULL:
710 if (cm->fuel_gauge) {
711 if (cm->fuel_gauge->get_property(cm->fuel_gauge,
712 POWER_SUPPLY_PROP_CHARGE_FULL, val) == 0)
713 break;
714 }
715
716 if (is_ext_pwr_online(cm)) {
717 /* Not full if it's charging. */
718 if (is_charging(cm)) {
719 val->intval = 0;
720 break;
721 }
722 /*
723 * Full if it's powered but not charging andi
724 * not forced stop by emergency
725 */
726 if (!cm->emergency_stop) {
727 val->intval = 1;
728 break;
729 }
730 }
731
732 /* Full if it's over the fullbatt voltage */
733 ret = get_batt_uV(cm, &uV);
734 if (!ret && desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV &&
735 !is_charging(cm)) {
736 val->intval = 1;
737 break;
738 }
739
740 /* Full if the cap is 100 */
741 if (cm->fuel_gauge) {
742 ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
743 POWER_SUPPLY_PROP_CAPACITY, val);
744 if (!ret && val->intval >= 100 && !is_charging(cm)) {
745 val->intval = 1;
746 break;
747 }
748 }
749
750 val->intval = 0;
751 ret = 0;
752 break;
753 case POWER_SUPPLY_PROP_CHARGE_NOW:
754 if (is_charging(cm)) {
755 ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
756 POWER_SUPPLY_PROP_CHARGE_NOW,
757 val);
758 if (ret) {
759 val->intval = 1;
760 ret = 0;
761 } else {
762 /* If CHARGE_NOW is supplied, use it */
763 val->intval = (val->intval > 0) ?
764 val->intval : 1;
765 }
766 } else {
767 val->intval = 0;
768 }
769 break;
770 default:
771 return -EINVAL;
772 }
773 return ret;
774 }
775
776 #define NUM_CHARGER_PSY_OPTIONAL (4)
777 static enum power_supply_property default_charger_props[] = {
778 /* Guaranteed to provide */
779 POWER_SUPPLY_PROP_STATUS,
780 POWER_SUPPLY_PROP_HEALTH,
781 POWER_SUPPLY_PROP_PRESENT,
782 POWER_SUPPLY_PROP_VOLTAGE_NOW,
783 POWER_SUPPLY_PROP_CAPACITY,
784 POWER_SUPPLY_PROP_ONLINE,
785 POWER_SUPPLY_PROP_CHARGE_FULL,
786 /*
787 * Optional properties are:
788 * POWER_SUPPLY_PROP_CHARGE_NOW,
789 * POWER_SUPPLY_PROP_CURRENT_NOW,
790 * POWER_SUPPLY_PROP_TEMP, and
791 * POWER_SUPPLY_PROP_TEMP_AMBIENT,
792 */
793 };
794
795 static struct power_supply psy_default = {
796 .name = "battery",
797 .type = POWER_SUPPLY_TYPE_BATTERY,
798 .properties = default_charger_props,
799 .num_properties = ARRAY_SIZE(default_charger_props),
800 .get_property = charger_get_property,
801 };
802
803 /**
804 * cm_setup_timer - For in-suspend monitoring setup wakeup alarm
805 * for suspend_again.
806 *
807 * Returns true if the alarm is set for Charger Manager to use.
808 * Returns false if
809 * cm_setup_timer fails to set an alarm,
810 * cm_setup_timer does not need to set an alarm for Charger Manager,
811 * or an alarm previously configured is to be used.
812 */
813 static bool cm_setup_timer(void)
814 {
815 struct charger_manager *cm;
816 unsigned int wakeup_ms = UINT_MAX;
817 bool ret = false;
818
819 mutex_lock(&cm_list_mtx);
820
821 list_for_each_entry(cm, &cm_list, entry) {
822 unsigned int fbchk_ms = 0;
823
824 /* fullbatt_vchk is required. setup timer for that */
825 if (cm->fullbatt_vchk_jiffies_at) {
826 fbchk_ms = jiffies_to_msecs(cm->fullbatt_vchk_jiffies_at
827 - jiffies);
828 if (time_is_before_eq_jiffies(
829 cm->fullbatt_vchk_jiffies_at) ||
830 msecs_to_jiffies(fbchk_ms) < CM_JIFFIES_SMALL) {
831 fullbatt_vchk(&cm->fullbatt_vchk_work.work);
832 fbchk_ms = 0;
833 }
834 }
835 CM_MIN_VALID(wakeup_ms, fbchk_ms);
836
837 /* Skip if polling is not required for this CM */
838 if (!is_polling_required(cm) && !cm->emergency_stop)
839 continue;
840 if (cm->desc->polling_interval_ms == 0)
841 continue;
842 CM_MIN_VALID(wakeup_ms, cm->desc->polling_interval_ms);
843 }
844
845 mutex_unlock(&cm_list_mtx);
846
847 if (wakeup_ms < UINT_MAX && wakeup_ms > 0) {
848 pr_info("Charger Manager wakeup timer: %u ms.\n", wakeup_ms);
849 if (rtc_dev) {
850 struct rtc_wkalrm tmp;
851 unsigned long time, now;
852 unsigned long add = DIV_ROUND_UP(wakeup_ms, 1000);
853
854 /*
855 * Set alarm with the polling interval (wakeup_ms)
856 * except when rtc_wkalarm_save comes first.
857 * However, the alarm time should be NOW +
858 * CM_RTC_SMALL or later.
859 */
860 tmp.enabled = 1;
861 rtc_read_time(rtc_dev, &tmp.time);
862 rtc_tm_to_time(&tmp.time, &now);
863 if (add < CM_RTC_SMALL)
864 add = CM_RTC_SMALL;
865 time = now + add;
866
867 ret = true;
868
869 if (rtc_wkalarm_save.enabled &&
870 rtc_wkalarm_save_time &&
871 rtc_wkalarm_save_time < time) {
872 if (rtc_wkalarm_save_time < now + CM_RTC_SMALL)
873 time = now + CM_RTC_SMALL;
874 else
875 time = rtc_wkalarm_save_time;
876
877 /* The timer is not appointed by CM */
878 ret = false;
879 }
880
881 pr_info("Waking up after %lu secs.\n",
882 time - now);
883
884 rtc_time_to_tm(time, &tmp.time);
885 rtc_set_alarm(rtc_dev, &tmp);
886 cm_suspend_duration_ms += wakeup_ms;
887 return ret;
888 }
889 }
890
891 if (rtc_dev)
892 rtc_set_alarm(rtc_dev, &rtc_wkalarm_save);
893 return false;
894 }
895
896 static void _cm_fbchk_in_suspend(struct charger_manager *cm)
897 {
898 unsigned long jiffy_now = jiffies;
899
900 if (!cm->fullbatt_vchk_jiffies_at)
901 return;
902
903 if (g_desc && g_desc->assume_timer_stops_in_suspend)
904 jiffy_now += msecs_to_jiffies(cm_suspend_duration_ms);
905
906 /* Execute now if it's going to be executed not too long after */
907 jiffy_now += CM_JIFFIES_SMALL;
908
909 if (time_after_eq(jiffy_now, cm->fullbatt_vchk_jiffies_at))
910 fullbatt_vchk(&cm->fullbatt_vchk_work.work);
911 }
912
913 /**
914 * cm_suspend_again - Determine whether suspend again or not
915 *
916 * Returns true if the system should be suspended again
917 * Returns false if the system should be woken up
918 */
919 bool cm_suspend_again(void)
920 {
921 struct charger_manager *cm;
922 bool ret = false;
923
924 if (!g_desc || !g_desc->rtc_only_wakeup || !g_desc->rtc_only_wakeup() ||
925 !cm_rtc_set)
926 return false;
927
928 if (cm_monitor())
929 goto out;
930
931 ret = true;
932 mutex_lock(&cm_list_mtx);
933 list_for_each_entry(cm, &cm_list, entry) {
934 _cm_fbchk_in_suspend(cm);
935
936 if (cm->status_save_ext_pwr_inserted != is_ext_pwr_online(cm) ||
937 cm->status_save_batt != is_batt_present(cm)) {
938 ret = false;
939 break;
940 }
941 }
942 mutex_unlock(&cm_list_mtx);
943
944 cm_rtc_set = cm_setup_timer();
945 out:
946 /* It's about the time when the non-CM appointed timer goes off */
947 if (rtc_wkalarm_save.enabled) {
948 unsigned long now;
949 struct rtc_time tmp;
950
951 rtc_read_time(rtc_dev, &tmp);
952 rtc_tm_to_time(&tmp, &now);
953
954 if (rtc_wkalarm_save_time &&
955 now + CM_RTC_SMALL >= rtc_wkalarm_save_time)
956 return false;
957 }
958 return ret;
959 }
960 EXPORT_SYMBOL_GPL(cm_suspend_again);
961
962 /**
963 * setup_charger_manager - initialize charger_global_desc data
964 * @gd: pointer to instance of charger_global_desc
965 */
966 int setup_charger_manager(struct charger_global_desc *gd)
967 {
968 if (!gd)
969 return -EINVAL;
970
971 if (rtc_dev)
972 rtc_class_close(rtc_dev);
973 rtc_dev = NULL;
974 g_desc = NULL;
975
976 if (!gd->rtc_only_wakeup) {
977 pr_err("The callback rtc_only_wakeup is not given.\n");
978 return -EINVAL;
979 }
980
981 if (gd->rtc_name) {
982 rtc_dev = rtc_class_open(gd->rtc_name);
983 if (IS_ERR_OR_NULL(rtc_dev)) {
984 rtc_dev = NULL;
985 /* Retry at probe. RTC may be not registered yet */
986 }
987 } else {
988 pr_warn("No wakeup timer is given for charger manager."
989 "In-suspend monitoring won't work.\n");
990 }
991
992 g_desc = gd;
993 return 0;
994 }
995 EXPORT_SYMBOL_GPL(setup_charger_manager);
996
997 static int charger_manager_probe(struct platform_device *pdev)
998 {
999 struct charger_desc *desc = dev_get_platdata(&pdev->dev);
1000 struct charger_manager *cm;
1001 int ret = 0, i = 0;
1002 union power_supply_propval val;
1003
1004 if (g_desc && !rtc_dev && g_desc->rtc_name) {
1005 rtc_dev = rtc_class_open(g_desc->rtc_name);
1006 if (IS_ERR_OR_NULL(rtc_dev)) {
1007 rtc_dev = NULL;
1008 dev_err(&pdev->dev, "Cannot get RTC %s.\n",
1009 g_desc->rtc_name);
1010 ret = -ENODEV;
1011 goto err_alloc;
1012 }
1013 }
1014
1015 if (!desc) {
1016 dev_err(&pdev->dev, "No platform data (desc) found.\n");
1017 ret = -ENODEV;
1018 goto err_alloc;
1019 }
1020
1021 cm = kzalloc(sizeof(struct charger_manager), GFP_KERNEL);
1022 if (!cm) {
1023 dev_err(&pdev->dev, "Cannot allocate memory.\n");
1024 ret = -ENOMEM;
1025 goto err_alloc;
1026 }
1027
1028 /* Basic Values. Unspecified are Null or 0 */
1029 cm->dev = &pdev->dev;
1030 cm->desc = kzalloc(sizeof(struct charger_desc), GFP_KERNEL);
1031 if (!cm->desc) {
1032 dev_err(&pdev->dev, "Cannot allocate memory.\n");
1033 ret = -ENOMEM;
1034 goto err_alloc_desc;
1035 }
1036 memcpy(cm->desc, desc, sizeof(struct charger_desc));
1037 cm->last_temp_mC = INT_MIN; /* denotes "unmeasured, yet" */
1038
1039 /*
1040 * The following two do not need to be errors.
1041 * Users may intentionally ignore those two features.
1042 */
1043 if (desc->fullbatt_uV == 0) {
1044 dev_info(&pdev->dev, "Ignoring full-battery voltage threshold"
1045 " as it is not supplied.");
1046 }
1047 if (!desc->fullbatt_vchkdrop_ms || !desc->fullbatt_vchkdrop_uV) {
1048 dev_info(&pdev->dev, "Disabling full-battery voltage drop "
1049 "checking mechanism as it is not supplied.");
1050 desc->fullbatt_vchkdrop_ms = 0;
1051 desc->fullbatt_vchkdrop_uV = 0;
1052 }
1053
1054 if (!desc->charger_regulators || desc->num_charger_regulators < 1) {
1055 ret = -EINVAL;
1056 dev_err(&pdev->dev, "charger_regulators undefined.\n");
1057 goto err_no_charger;
1058 }
1059
1060 if (!desc->psy_charger_stat || !desc->psy_charger_stat[0]) {
1061 dev_err(&pdev->dev, "No power supply defined.\n");
1062 ret = -EINVAL;
1063 goto err_no_charger_stat;
1064 }
1065
1066 /* Counting index only */
1067 while (desc->psy_charger_stat[i])
1068 i++;
1069
1070 cm->charger_stat = kzalloc(sizeof(struct power_supply *) * (i + 1),
1071 GFP_KERNEL);
1072 if (!cm->charger_stat) {
1073 ret = -ENOMEM;
1074 goto err_no_charger_stat;
1075 }
1076
1077 for (i = 0; desc->psy_charger_stat[i]; i++) {
1078 cm->charger_stat[i] = power_supply_get_by_name(
1079 desc->psy_charger_stat[i]);
1080 if (!cm->charger_stat[i]) {
1081 dev_err(&pdev->dev, "Cannot find power supply "
1082 "\"%s\"\n",
1083 desc->psy_charger_stat[i]);
1084 ret = -ENODEV;
1085 goto err_chg_stat;
1086 }
1087 }
1088
1089 cm->fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge);
1090 if (!cm->fuel_gauge) {
1091 dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n",
1092 desc->psy_fuel_gauge);
1093 ret = -ENODEV;
1094 goto err_chg_stat;
1095 }
1096
1097 if (desc->polling_interval_ms == 0 ||
1098 msecs_to_jiffies(desc->polling_interval_ms) <= CM_JIFFIES_SMALL) {
1099 dev_err(&pdev->dev, "polling_interval_ms is too small\n");
1100 ret = -EINVAL;
1101 goto err_chg_stat;
1102 }
1103
1104 if (!desc->temperature_out_of_range) {
1105 dev_err(&pdev->dev, "there is no temperature_out_of_range\n");
1106 ret = -EINVAL;
1107 goto err_chg_stat;
1108 }
1109
1110 platform_set_drvdata(pdev, cm);
1111
1112 memcpy(&cm->charger_psy, &psy_default, sizeof(psy_default));
1113
1114 if (!desc->psy_name) {
1115 strncpy(cm->psy_name_buf, psy_default.name, PSY_NAME_MAX);
1116 } else {
1117 strncpy(cm->psy_name_buf, desc->psy_name, PSY_NAME_MAX);
1118 }
1119 cm->charger_psy.name = cm->psy_name_buf;
1120
1121 /* Allocate for psy properties because they may vary */
1122 cm->charger_psy.properties = kzalloc(sizeof(enum power_supply_property)
1123 * (ARRAY_SIZE(default_charger_props) +
1124 NUM_CHARGER_PSY_OPTIONAL),
1125 GFP_KERNEL);
1126 if (!cm->charger_psy.properties) {
1127 dev_err(&pdev->dev, "Cannot allocate for psy properties.\n");
1128 ret = -ENOMEM;
1129 goto err_chg_stat;
1130 }
1131 memcpy(cm->charger_psy.properties, default_charger_props,
1132 sizeof(enum power_supply_property) *
1133 ARRAY_SIZE(default_charger_props));
1134 cm->charger_psy.num_properties = psy_default.num_properties;
1135
1136 /* Find which optional psy-properties are available */
1137 if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
1138 POWER_SUPPLY_PROP_CHARGE_NOW, &val)) {
1139 cm->charger_psy.properties[cm->charger_psy.num_properties] =
1140 POWER_SUPPLY_PROP_CHARGE_NOW;
1141 cm->charger_psy.num_properties++;
1142 }
1143 if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
1144 POWER_SUPPLY_PROP_CURRENT_NOW,
1145 &val)) {
1146 cm->charger_psy.properties[cm->charger_psy.num_properties] =
1147 POWER_SUPPLY_PROP_CURRENT_NOW;
1148 cm->charger_psy.num_properties++;
1149 }
1150
1151 if (desc->measure_battery_temp) {
1152 cm->charger_psy.properties[cm->charger_psy.num_properties] =
1153 POWER_SUPPLY_PROP_TEMP;
1154 cm->charger_psy.num_properties++;
1155 } else {
1156 cm->charger_psy.properties[cm->charger_psy.num_properties] =
1157 POWER_SUPPLY_PROP_TEMP_AMBIENT;
1158 cm->charger_psy.num_properties++;
1159 }
1160
1161 INIT_DELAYED_WORK(&cm->fullbatt_vchk_work, fullbatt_vchk);
1162
1163 ret = power_supply_register(NULL, &cm->charger_psy);
1164 if (ret) {
1165 dev_err(&pdev->dev, "Cannot register charger-manager with"
1166 " name \"%s\".\n", cm->charger_psy.name);
1167 goto err_register;
1168 }
1169
1170 ret = regulator_bulk_get(&pdev->dev, desc->num_charger_regulators,
1171 desc->charger_regulators);
1172 if (ret) {
1173 dev_err(&pdev->dev, "Cannot get charger regulators.\n");
1174 goto err_bulk_get;
1175 }
1176
1177 ret = try_charger_enable(cm, true);
1178 if (ret) {
1179 dev_err(&pdev->dev, "Cannot enable charger regulators\n");
1180 goto err_chg_enable;
1181 }
1182
1183 /* Add to the list */
1184 mutex_lock(&cm_list_mtx);
1185 list_add(&cm->entry, &cm_list);
1186 mutex_unlock(&cm_list_mtx);
1187
1188 /*
1189 * Charger-manager is capable of waking up the systme from sleep
1190 * when event is happend through cm_notify_event()
1191 */
1192 device_init_wakeup(&pdev->dev, true);
1193 device_set_wakeup_capable(&pdev->dev, false);
1194
1195 schedule_work(&setup_polling);
1196
1197 return 0;
1198
1199 err_chg_enable:
1200 regulator_bulk_free(desc->num_charger_regulators,
1201 desc->charger_regulators);
1202 err_bulk_get:
1203 power_supply_unregister(&cm->charger_psy);
1204 err_register:
1205 kfree(cm->charger_psy.properties);
1206 err_chg_stat:
1207 kfree(cm->charger_stat);
1208 err_no_charger_stat:
1209 err_no_charger:
1210 kfree(cm->desc);
1211 err_alloc_desc:
1212 kfree(cm);
1213 err_alloc:
1214 return ret;
1215 }
1216
1217 static int __devexit charger_manager_remove(struct platform_device *pdev)
1218 {
1219 struct charger_manager *cm = platform_get_drvdata(pdev);
1220 struct charger_desc *desc = cm->desc;
1221
1222 /* Remove from the list */
1223 mutex_lock(&cm_list_mtx);
1224 list_del(&cm->entry);
1225 mutex_unlock(&cm_list_mtx);
1226
1227 if (work_pending(&setup_polling))
1228 cancel_work_sync(&setup_polling);
1229 if (delayed_work_pending(&cm_monitor_work))
1230 cancel_delayed_work_sync(&cm_monitor_work);
1231
1232 regulator_bulk_free(desc->num_charger_regulators,
1233 desc->charger_regulators);
1234 power_supply_unregister(&cm->charger_psy);
1235
1236 try_charger_enable(cm, false);
1237
1238 kfree(cm->charger_psy.properties);
1239 kfree(cm->charger_stat);
1240 kfree(cm->desc);
1241 kfree(cm);
1242
1243 return 0;
1244 }
1245
1246 static const struct platform_device_id charger_manager_id[] = {
1247 { "charger-manager", 0 },
1248 { },
1249 };
1250 MODULE_DEVICE_TABLE(platform, charger_manager_id);
1251
1252 static int cm_suspend_noirq(struct device *dev)
1253 {
1254 int ret = 0;
1255
1256 if (device_may_wakeup(dev)) {
1257 device_set_wakeup_capable(dev, false);
1258 ret = -EAGAIN;
1259 }
1260
1261 return ret;
1262 }
1263
1264 static int cm_suspend_prepare(struct device *dev)
1265 {
1266 struct charger_manager *cm = dev_get_drvdata(dev);
1267
1268 if (!cm_suspended) {
1269 if (rtc_dev) {
1270 struct rtc_time tmp;
1271 unsigned long now;
1272
1273 rtc_read_alarm(rtc_dev, &rtc_wkalarm_save);
1274 rtc_read_time(rtc_dev, &tmp);
1275
1276 if (rtc_wkalarm_save.enabled) {
1277 rtc_tm_to_time(&rtc_wkalarm_save.time,
1278 &rtc_wkalarm_save_time);
1279 rtc_tm_to_time(&tmp, &now);
1280 if (now > rtc_wkalarm_save_time)
1281 rtc_wkalarm_save_time = 0;
1282 } else {
1283 rtc_wkalarm_save_time = 0;
1284 }
1285 }
1286 cm_suspended = true;
1287 }
1288
1289 if (delayed_work_pending(&cm->fullbatt_vchk_work))
1290 cancel_delayed_work(&cm->fullbatt_vchk_work);
1291 cm->status_save_ext_pwr_inserted = is_ext_pwr_online(cm);
1292 cm->status_save_batt = is_batt_present(cm);
1293
1294 if (!cm_rtc_set) {
1295 cm_suspend_duration_ms = 0;
1296 cm_rtc_set = cm_setup_timer();
1297 }
1298
1299 return 0;
1300 }
1301
1302 static void cm_suspend_complete(struct device *dev)
1303 {
1304 struct charger_manager *cm = dev_get_drvdata(dev);
1305
1306 if (cm_suspended) {
1307 if (rtc_dev) {
1308 struct rtc_wkalrm tmp;
1309
1310 rtc_read_alarm(rtc_dev, &tmp);
1311 rtc_wkalarm_save.pending = tmp.pending;
1312 rtc_set_alarm(rtc_dev, &rtc_wkalarm_save);
1313 }
1314 cm_suspended = false;
1315 cm_rtc_set = false;
1316 }
1317
1318 /* Re-enqueue delayed work (fullbatt_vchk_work) */
1319 if (cm->fullbatt_vchk_jiffies_at) {
1320 unsigned long delay = 0;
1321 unsigned long now = jiffies + CM_JIFFIES_SMALL;
1322
1323 if (time_after_eq(now, cm->fullbatt_vchk_jiffies_at)) {
1324 delay = (unsigned long)((long)now
1325 - (long)(cm->fullbatt_vchk_jiffies_at));
1326 delay = jiffies_to_msecs(delay);
1327 } else {
1328 delay = 0;
1329 }
1330
1331 /*
1332 * Account for cm_suspend_duration_ms if
1333 * assume_timer_stops_in_suspend is active
1334 */
1335 if (g_desc && g_desc->assume_timer_stops_in_suspend) {
1336 if (delay > cm_suspend_duration_ms)
1337 delay -= cm_suspend_duration_ms;
1338 else
1339 delay = 0;
1340 }
1341
1342 queue_delayed_work(cm_wq, &cm->fullbatt_vchk_work,
1343 msecs_to_jiffies(delay));
1344 }
1345 device_set_wakeup_capable(cm->dev, false);
1346 uevent_notify(cm, NULL);
1347 }
1348
1349 static const struct dev_pm_ops charger_manager_pm = {
1350 .prepare = cm_suspend_prepare,
1351 .suspend_noirq = cm_suspend_noirq,
1352 .complete = cm_suspend_complete,
1353 };
1354
1355 static struct platform_driver charger_manager_driver = {
1356 .driver = {
1357 .name = "charger-manager",
1358 .owner = THIS_MODULE,
1359 .pm = &charger_manager_pm,
1360 },
1361 .probe = charger_manager_probe,
1362 .remove = __devexit_p(charger_manager_remove),
1363 .id_table = charger_manager_id,
1364 };
1365
1366 static int __init charger_manager_init(void)
1367 {
1368 cm_wq = create_freezable_workqueue("charger_manager");
1369 INIT_DELAYED_WORK(&cm_monitor_work, cm_monitor_poller);
1370
1371 return platform_driver_register(&charger_manager_driver);
1372 }
1373 late_initcall(charger_manager_init);
1374
1375 static void __exit charger_manager_cleanup(void)
1376 {
1377 destroy_workqueue(cm_wq);
1378 cm_wq = NULL;
1379
1380 platform_driver_unregister(&charger_manager_driver);
1381 }
1382 module_exit(charger_manager_cleanup);
1383
1384 /**
1385 * find_power_supply - find the associated power_supply of charger
1386 * @cm: the Charger Manager representing the battery
1387 * @psy: pointer to instance of charger's power_supply
1388 */
1389 static bool find_power_supply(struct charger_manager *cm,
1390 struct power_supply *psy)
1391 {
1392 int i;
1393 bool found = false;
1394
1395 for (i = 0; cm->charger_stat[i]; i++) {
1396 if (psy == cm->charger_stat[i]) {
1397 found = true;
1398 break;
1399 }
1400 }
1401
1402 return found;
1403 }
1404
1405 /**
1406 * cm_notify_event - charger driver notify Charger Manager of charger event
1407 * @psy: pointer to instance of charger's power_supply
1408 * @type: type of charger event
1409 * @msg: optional message passed to uevent_notify fuction
1410 */
1411 void cm_notify_event(struct power_supply *psy, enum cm_event_types type,
1412 char *msg)
1413 {
1414 struct charger_manager *cm;
1415 bool found_power_supply = false;
1416
1417 if (psy == NULL)
1418 return;
1419
1420 mutex_lock(&cm_list_mtx);
1421 list_for_each_entry(cm, &cm_list, entry) {
1422 found_power_supply = find_power_supply(cm, psy);
1423 if (found_power_supply)
1424 break;
1425 }
1426 mutex_unlock(&cm_list_mtx);
1427
1428 if (!found_power_supply)
1429 return;
1430
1431 switch (type) {
1432 case CM_EVENT_BATT_FULL:
1433 fullbatt_handler(cm);
1434 break;
1435 case CM_EVENT_BATT_OUT:
1436 battout_handler(cm);
1437 break;
1438 case CM_EVENT_BATT_IN:
1439 case CM_EVENT_EXT_PWR_IN_OUT ... CM_EVENT_CHG_START_STOP:
1440 misc_event_handler(cm, type);
1441 break;
1442 case CM_EVENT_UNKNOWN:
1443 case CM_EVENT_OTHERS:
1444 uevent_notify(cm, msg ? msg : default_event_names[type]);
1445 break;
1446 default:
1447 dev_err(cm->dev, "%s type not specified.\n", __func__);
1448 break;
1449 }
1450 }
1451 EXPORT_SYMBOL_GPL(cm_notify_event);
1452
1453 MODULE_AUTHOR("MyungJoo Ham <myungjoo.ham@samsung.com>");
1454 MODULE_DESCRIPTION("Charger Manager");
1455 MODULE_LICENSE("GPL");
This page took 0.075981 seconds and 5 git commands to generate.