IB/qib: Fix issue with link states and QSFP cables
[deliverable/linux.git] / drivers / scsi / Kconfig
1 menu "SCSI device support"
2
3 config SCSI_MOD
4 tristate
5 default y if SCSI=n || SCSI=y
6 default m if SCSI=m
7
8 config RAID_ATTRS
9 tristate "RAID Transport Class"
10 default n
11 depends on BLOCK
12 depends on SCSI_MOD
13 ---help---
14 Provides RAID
15
16 config SCSI
17 tristate "SCSI device support"
18 depends on BLOCK
19 select SCSI_DMA if HAS_DMA
20 ---help---
21 If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
22 any other SCSI device under Linux, say Y and make sure that you know
23 the name of your SCSI host adapter (the card inside your computer
24 that "speaks" the SCSI protocol, also called SCSI controller),
25 because you will be asked for it.
26
27 You also need to say Y here if you have a device which speaks
28 the SCSI protocol. Examples of this include the parallel port
29 version of the IOMEGA ZIP drive, USB storage devices, Fibre
30 Channel, and FireWire storage.
31
32 To compile this driver as a module, choose M here and read
33 <file:Documentation/scsi/scsi.txt>.
34 The module will be called scsi_mod.
35
36 However, do not compile this as a module if your root file system
37 (the one containing the directory /) is located on a SCSI device.
38
39 config SCSI_DMA
40 bool
41 default n
42
43 config SCSI_TGT
44 tristate "SCSI target support"
45 depends on SCSI && EXPERIMENTAL
46 ---help---
47 If you want to use SCSI target mode drivers enable this option.
48 If you choose M, the module will be called scsi_tgt.
49
50 config SCSI_NETLINK
51 bool
52 default n
53 select NET
54
55 config SCSI_PROC_FS
56 bool "legacy /proc/scsi/ support"
57 depends on SCSI && PROC_FS
58 default y
59 ---help---
60 This option enables support for the various files in
61 /proc/scsi. In Linux 2.6 this has been superseded by
62 files in sysfs but many legacy applications rely on this.
63
64 If unsure say Y.
65
66 comment "SCSI support type (disk, tape, CD-ROM)"
67 depends on SCSI
68
69 config BLK_DEV_SD
70 tristate "SCSI disk support"
71 depends on SCSI
72 select CRC_T10DIF if BLK_DEV_INTEGRITY
73 ---help---
74 If you want to use SCSI hard disks, Fibre Channel disks,
75 Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
76 USB storage or the SCSI or parallel port version of
77 the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
78 the Disk-HOWTO and the Multi-Disk-HOWTO, available from
79 <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
80 CD-ROMs.
81
82 To compile this driver as a module, choose M here and read
83 <file:Documentation/scsi/scsi.txt>.
84 The module will be called sd_mod.
85
86 Do not compile this driver as a module if your root file system
87 (the one containing the directory /) is located on a SCSI disk.
88 In this case, do not compile the driver for your SCSI host adapter
89 (below) as a module either.
90
91 config CHR_DEV_ST
92 tristate "SCSI tape support"
93 depends on SCSI
94 ---help---
95 If you want to use a SCSI tape drive under Linux, say Y and read the
96 SCSI-HOWTO, available from
97 <http://www.tldp.org/docs.html#howto>, and
98 <file:Documentation/scsi/st.txt> in the kernel source. This is NOT
99 for SCSI CD-ROMs.
100
101 To compile this driver as a module, choose M here and read
102 <file:Documentation/scsi/scsi.txt>. The module will be called st.
103
104 config CHR_DEV_OSST
105 tristate "SCSI OnStream SC-x0 tape support"
106 depends on SCSI
107 ---help---
108 The OnStream SC-x0 SCSI tape drives cannot be driven by the
109 standard st driver, but instead need this special osst driver and
110 use the /dev/osstX char device nodes (major 206). Via usb-storage,
111 you may be able to drive the USB-x0 and DI-x0 drives as well.
112 Note that there is also a second generation of OnStream
113 tape drives (ADR-x0) that supports the standard SCSI-2 commands for
114 tapes (QIC-157) and can be driven by the standard driver st.
115 For more information, you may have a look at the SCSI-HOWTO
116 <http://www.tldp.org/docs.html#howto> and
117 <file:Documentation/scsi/osst.txt> in the kernel source.
118 More info on the OnStream driver may be found on
119 <http://sourceforge.net/projects/osst/>
120 Please also have a look at the standard st docu, as most of it
121 applies to osst as well.
122
123 To compile this driver as a module, choose M here and read
124 <file:Documentation/scsi/scsi.txt>. The module will be called osst.
125
126 config BLK_DEV_SR
127 tristate "SCSI CDROM support"
128 depends on SCSI
129 ---help---
130 If you want to use a CD or DVD drive attached to your computer
131 by SCSI, FireWire, USB or ATAPI, say Y and read the SCSI-HOWTO
132 and the CDROM-HOWTO at <http://www.tldp.org/docs.html#howto>.
133
134 Make sure to say Y or M to "ISO 9660 CD-ROM file system support".
135
136 To compile this driver as a module, choose M here and read
137 <file:Documentation/scsi/scsi.txt>.
138 The module will be called sr_mod.
139
140 config BLK_DEV_SR_VENDOR
141 bool "Enable vendor-specific extensions (for SCSI CDROM)"
142 depends on BLK_DEV_SR
143 help
144 This enables the usage of vendor specific SCSI commands. This is
145 required to support multisession CDs with old NEC/TOSHIBA cdrom
146 drives (and HP Writers). If you have such a drive and get the first
147 session only, try saying Y here; everybody else says N.
148
149 config CHR_DEV_SG
150 tristate "SCSI generic support"
151 depends on SCSI
152 ---help---
153 If you want to use SCSI scanners, synthesizers or CD-writers or just
154 about anything having "SCSI" in its name other than hard disks,
155 CD-ROMs or tapes, say Y here. These won't be supported by the kernel
156 directly, so you need some additional software which knows how to
157 talk to these devices using the SCSI protocol:
158
159 For scanners, look at SANE (<http://www.sane-project.org/>). For CD
160 writer software look at Cdrtools
161 (<http://cdrecord.berlios.de/private/cdrecord.html>)
162 and for burning a "disk at once": CDRDAO
163 (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
164 quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
165 For other devices, it's possible that you'll have to write the
166 driver software yourself. Please read the file
167 <file:Documentation/scsi/scsi-generic.txt> for more information.
168
169 To compile this driver as a module, choose M here and read
170 <file:Documentation/scsi/scsi.txt>. The module will be called sg.
171
172 If unsure, say N.
173
174 config CHR_DEV_SCH
175 tristate "SCSI media changer support"
176 depends on SCSI
177 ---help---
178 This is a driver for SCSI media changers. Most common devices are
179 tape libraries and MOD/CDROM jukeboxes. *Real* jukeboxes, you
180 don't need this for those tiny 6-slot cdrom changers. Media
181 changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
182 If you have such hardware and want to use it with linux, say Y
183 here. Check <file:Documentation/scsi/scsi-changer.txt> for details.
184
185 If you want to compile this as a module ( = code which can be
186 inserted in and removed from the running kernel whenever you want),
187 say M here and read <file:Documentation/kbuild/modules.txt> and
188 <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
189 If unsure, say N.
190
191 config SCSI_ENCLOSURE
192 tristate "SCSI Enclosure Support"
193 depends on SCSI && ENCLOSURE_SERVICES
194 help
195 Enclosures are devices sitting on or in SCSI backplanes that
196 manage devices. If you have a disk cage, the chances are that
197 it has an enclosure device. Selecting this option will just allow
198 certain enclosure conditions to be reported and is not required.
199
200 config SCSI_MULTI_LUN
201 bool "Probe all LUNs on each SCSI device"
202 depends on SCSI
203 help
204 Some devices support more than one LUN (Logical Unit Number) in order
205 to allow access to several media, e.g. CD jukebox, USB card reader,
206 mobile phone in mass storage mode. This option forces the kernel to
207 probe for all LUNs by default. This setting can be overriden by
208 max_luns boot/module parameter. Note that this option does not affect
209 devices conforming to SCSI-3 or higher as they can explicitely report
210 their number of LUNs. It is safe to say Y here unless you have one of
211 those rare devices which reacts in an unexpected way when probed for
212 multiple LUNs.
213
214 config SCSI_CONSTANTS
215 bool "Verbose SCSI error reporting (kernel size +=12K)"
216 depends on SCSI
217 help
218 The error messages regarding your SCSI hardware will be easier to
219 understand if you say Y here; it will enlarge your kernel by about
220 12 KB. If in doubt, say Y.
221
222 config SCSI_LOGGING
223 bool "SCSI logging facility"
224 depends on SCSI
225 ---help---
226 This turns on a logging facility that can be used to debug a number
227 of SCSI related problems.
228
229 If you say Y here, no logging output will appear by default, but you
230 can enable logging by saying Y to "/proc file system support" and
231 "Sysctl support" below and executing the command
232
233 echo <bitmask> > /proc/sys/dev/scsi/logging_level
234
235 where <bitmask> is a four byte value representing the logging type
236 and logging level for each type of logging selected.
237
238 There are a number of logging types and you can find them in the
239 source at <file:drivers/scsi/scsi_logging.h>. The logging levels
240 are also described in that file and they determine the verbosity of
241 the logging for each logging type.
242
243 If you say N here, it may be harder to track down some types of SCSI
244 problems. If you say Y here your kernel will be somewhat larger, but
245 there should be no noticeable performance impact as long as you have
246 logging turned off.
247
248 config SCSI_SCAN_ASYNC
249 bool "Asynchronous SCSI scanning"
250 depends on SCSI
251 help
252 The SCSI subsystem can probe for devices while the rest of the
253 system continues booting, and even probe devices on different
254 busses in parallel, leading to a significant speed-up.
255
256 If you have built SCSI as modules, enabling this option can
257 be a problem as the devices may not have been found by the
258 time your system expects them to have been. You can load the
259 scsi_wait_scan module to ensure that all scans have completed.
260 If you build your SCSI drivers into the kernel, then everything
261 will work fine if you say Y here.
262
263 You can override this choice by specifying "scsi_mod.scan=sync"
264 or async on the kernel's command line.
265
266 config SCSI_WAIT_SCAN
267 tristate # No prompt here, this is an invisible symbol.
268 default m
269 depends on SCSI
270 depends on MODULES
271 # scsi_wait_scan is a loadable module which waits until all the async scans are
272 # complete. The idea is to use it in initrd/ initramfs scripts. You modprobe
273 # it after all the modprobes of the root SCSI drivers and it will wait until
274 # they have all finished scanning their buses before allowing the boot to
275 # proceed. (This method is not applicable if targets boot independently in
276 # parallel with the initiator, or with transports with non-deterministic target
277 # discovery schemes, or if a transport driver does not support scsi_wait_scan.)
278 #
279 # This symbol is not exposed as a prompt because little is to be gained by
280 # disabling it, whereas people who accidentally switch it off may wonder why
281 # their mkinitrd gets into trouble.
282
283 menu "SCSI Transports"
284 depends on SCSI
285
286 config SCSI_SPI_ATTRS
287 tristate "Parallel SCSI (SPI) Transport Attributes"
288 depends on SCSI
289 help
290 If you wish to export transport-specific information about
291 each attached SCSI device to sysfs, say Y. Otherwise, say N.
292
293 config SCSI_FC_ATTRS
294 tristate "FiberChannel Transport Attributes"
295 depends on SCSI
296 select SCSI_NETLINK
297 help
298 If you wish to export transport-specific information about
299 each attached FiberChannel device to sysfs, say Y.
300 Otherwise, say N.
301
302 config SCSI_FC_TGT_ATTRS
303 bool "SCSI target support for FiberChannel Transport Attributes"
304 depends on SCSI_FC_ATTRS
305 depends on SCSI_TGT = y || SCSI_TGT = SCSI_FC_ATTRS
306 help
307 If you want to use SCSI target mode drivers enable this option.
308
309 config SCSI_ISCSI_ATTRS
310 tristate "iSCSI Transport Attributes"
311 depends on SCSI && NET
312 help
313 If you wish to export transport-specific information about
314 each attached iSCSI device to sysfs, say Y.
315 Otherwise, say N.
316
317 config SCSI_SAS_ATTRS
318 tristate "SAS Transport Attributes"
319 depends on SCSI
320 select BLK_DEV_BSG
321 help
322 If you wish to export transport-specific information about
323 each attached SAS device to sysfs, say Y.
324
325 source "drivers/scsi/libsas/Kconfig"
326
327 config SCSI_SRP_ATTRS
328 tristate "SRP Transport Attributes"
329 depends on SCSI
330 help
331 If you wish to export transport-specific information about
332 each attached SRP device to sysfs, say Y.
333
334 config SCSI_SRP_TGT_ATTRS
335 bool "SCSI target support for SRP Transport Attributes"
336 depends on SCSI_SRP_ATTRS
337 depends on SCSI_TGT = y || SCSI_TGT = SCSI_SRP_ATTRS
338 help
339 If you want to use SCSI target mode drivers enable this option.
340
341 endmenu
342
343 menuconfig SCSI_LOWLEVEL
344 bool "SCSI low-level drivers"
345 depends on SCSI!=n
346 default y
347
348 if SCSI_LOWLEVEL && SCSI
349
350 config ISCSI_TCP
351 tristate "iSCSI Initiator over TCP/IP"
352 depends on SCSI && INET
353 select CRYPTO
354 select CRYPTO_MD5
355 select CRYPTO_CRC32C
356 select SCSI_ISCSI_ATTRS
357 help
358 The iSCSI Driver provides a host with the ability to access storage
359 through an IP network. The driver uses the iSCSI protocol to transport
360 SCSI requests and responses over a TCP/IP network between the host
361 (the "initiator") and "targets". Architecturally, the iSCSI driver
362 combines with the host's TCP/IP stack, network drivers, and Network
363 Interface Card (NIC) to provide the same functions as a SCSI or a
364 Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
365
366 To compile this driver as a module, choose M here: the
367 module will be called iscsi_tcp.
368
369 The userspace component needed to initialize the driver, documentation,
370 and sample configuration files can be found here:
371
372 http://open-iscsi.org
373
374 config ISCSI_BOOT_SYSFS
375 tristate "iSCSI Boot Sysfs Interface"
376 default n
377 help
378 This option enables support for exposing iSCSI boot information
379 via sysfs to userspace. If you wish to export this information,
380 say Y. Otherwise, say N.
381
382 source "drivers/scsi/cxgbi/Kconfig"
383 source "drivers/scsi/bnx2i/Kconfig"
384 source "drivers/scsi/bnx2fc/Kconfig"
385 source "drivers/scsi/be2iscsi/Kconfig"
386
387 config SGIWD93_SCSI
388 tristate "SGI WD93C93 SCSI Driver"
389 depends on SGI_HAS_WD93 && SCSI
390 help
391 If you have a Western Digital WD93 SCSI controller on
392 an SGI MIPS system, say Y. Otherwise, say N.
393
394 config BLK_DEV_3W_XXXX_RAID
395 tristate "3ware 5/6/7/8xxx ATA-RAID support"
396 depends on PCI && SCSI
397 help
398 3ware is the only hardware ATA-Raid product in Linux to date.
399 This card is 2,4, or 8 channel master mode support only.
400 SCSI support required!!!
401
402 <http://www.3ware.com/>
403
404 Please read the comments at the top of
405 <file:drivers/scsi/3w-xxxx.c>.
406
407 config SCSI_HPSA
408 tristate "HP Smart Array SCSI driver"
409 depends on PCI && SCSI
410 help
411 This driver supports HP Smart Array Controllers (circa 2009).
412 It is a SCSI alternative to the cciss driver, which is a block
413 driver. Anyone wishing to use HP Smart Array controllers who
414 would prefer the devices be presented to linux as SCSI devices,
415 rather than as generic block devices should say Y here.
416
417 config SCSI_3W_9XXX
418 tristate "3ware 9xxx SATA-RAID support"
419 depends on PCI && SCSI
420 help
421 This driver supports the 9000 series 3ware SATA-RAID cards.
422
423 <http://www.amcc.com>
424
425 Please read the comments at the top of
426 <file:drivers/scsi/3w-9xxx.c>.
427
428 config SCSI_3W_SAS
429 tristate "3ware 97xx SAS/SATA-RAID support"
430 depends on PCI && SCSI
431 help
432 This driver supports the LSI 3ware 9750 6Gb/s SAS/SATA-RAID cards.
433
434 <http://www.lsi.com>
435
436 Please read the comments at the top of
437 <file:drivers/scsi/3w-sas.c>.
438
439 config SCSI_7000FASST
440 tristate "7000FASST SCSI support"
441 depends on ISA && SCSI && ISA_DMA_API
442 select CHECK_SIGNATURE
443 help
444 This driver supports the Western Digital 7000 SCSI host adapter
445 family. Some information is in the source:
446 <file:drivers/scsi/wd7000.c>.
447
448 To compile this driver as a module, choose M here: the
449 module will be called wd7000.
450
451 config SCSI_ACARD
452 tristate "ACARD SCSI support"
453 depends on PCI && SCSI
454 help
455 This driver supports the ACARD SCSI host adapter.
456 Support Chip <ATP870 ATP876 ATP880 ATP885>
457 To compile this driver as a module, choose M here: the
458 module will be called atp870u.
459
460 config SCSI_AHA152X
461 tristate "Adaptec AHA152X/2825 support"
462 depends on ISA && SCSI && !64BIT
463 select SCSI_SPI_ATTRS
464 select CHECK_SIGNATURE
465 ---help---
466 This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
467 SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
468 must be manually specified in this case.
469
470 It is explained in section 3.3 of the SCSI-HOWTO, available from
471 <http://www.tldp.org/docs.html#howto>. You might also want to
472 read the file <file:Documentation/scsi/aha152x.txt>.
473
474 To compile this driver as a module, choose M here: the
475 module will be called aha152x.
476
477 config SCSI_AHA1542
478 tristate "Adaptec AHA1542 support"
479 depends on ISA && SCSI && ISA_DMA_API
480 ---help---
481 This is support for a SCSI host adapter. It is explained in section
482 3.4 of the SCSI-HOWTO, available from
483 <http://www.tldp.org/docs.html#howto>. Note that Trantor was
484 purchased by Adaptec, and some former Trantor products are being
485 sold under the Adaptec name. If it doesn't work out of the box, you
486 may have to change some settings in <file:drivers/scsi/aha1542.h>.
487
488 To compile this driver as a module, choose M here: the
489 module will be called aha1542.
490
491 config SCSI_AHA1740
492 tristate "Adaptec AHA1740 support"
493 depends on EISA && SCSI
494 ---help---
495 This is support for a SCSI host adapter. It is explained in section
496 3.5 of the SCSI-HOWTO, available from
497 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
498 of the box, you may have to change some settings in
499 <file:drivers/scsi/aha1740.h>.
500
501 To compile this driver as a module, choose M here: the
502 module will be called aha1740.
503
504 config SCSI_AACRAID
505 tristate "Adaptec AACRAID support"
506 depends on SCSI && PCI
507 help
508 This driver supports a variety of Dell, HP, Adaptec, IBM and
509 ICP storage products. For a list of supported products, refer
510 to <file:Documentation/scsi/aacraid.txt>.
511
512 To compile this driver as a module, choose M here: the module
513 will be called aacraid.
514
515
516 source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
517
518 config SCSI_AIC7XXX_OLD
519 tristate "Adaptec AIC7xxx support (old driver)"
520 depends on (ISA || EISA || PCI ) && SCSI
521 help
522 WARNING This driver is an older aic7xxx driver and is no longer
523 under active development. Adaptec, Inc. is writing a new driver to
524 take the place of this one, and it is recommended that whenever
525 possible, people should use the new Adaptec written driver instead
526 of this one. This driver will eventually be phased out entirely.
527
528 This is support for the various aic7xxx based Adaptec SCSI
529 controllers. These include the 274x EISA cards; 284x VLB cards;
530 2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
531 motherboard based SCSI controllers from Adaptec. It does not support
532 the AAA-13x RAID controllers from Adaptec, nor will it likely ever
533 support them. It does not support the 2920 cards from Adaptec that
534 use the Future Domain SCSI controller chip. For those cards, you
535 need the "Future Domain 16xx SCSI support" driver.
536
537 In general, if the controller is based on an Adaptec SCSI controller
538 chip from the aic777x series or the aic78xx series, this driver
539 should work. The only exception is the 7810 which is specifically
540 not supported (that's the RAID controller chip on the AAA-13x
541 cards).
542
543 Note that the AHA2920 SCSI host adapter is *not* supported by this
544 driver; choose "Future Domain 16xx SCSI support" instead if you have
545 one of those.
546
547 Information on the configuration options for this controller can be
548 found by checking the help file for each of the available
549 configuration options. You should read
550 <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
551 contacting the maintainer with any questions. The SCSI-HOWTO,
552 available from <http://www.tldp.org/docs.html#howto>, can also
553 be of great help.
554
555 To compile this driver as a module, choose M here: the
556 module will be called aic7xxx_old.
557
558 source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
559 source "drivers/scsi/aic94xx/Kconfig"
560 source "drivers/scsi/mvsas/Kconfig"
561
562 config SCSI_DPT_I2O
563 tristate "Adaptec I2O RAID support "
564 depends on SCSI && PCI && VIRT_TO_BUS
565 help
566 This driver supports all of Adaptec's I2O based RAID controllers as
567 well as the DPT SmartRaid V cards. This is an Adaptec maintained
568 driver by Deanna Bonds. See <file:Documentation/scsi/dpti.txt>.
569
570 To compile this driver as a module, choose M here: the
571 module will be called dpt_i2o.
572
573 config SCSI_ADVANSYS
574 tristate "AdvanSys SCSI support"
575 depends on SCSI && VIRT_TO_BUS
576 depends on ISA || EISA || PCI
577 help
578 This is a driver for all SCSI host adapters manufactured by
579 AdvanSys. It is documented in the kernel source in
580 <file:drivers/scsi/advansys.c>.
581
582 To compile this driver as a module, choose M here: the
583 module will be called advansys.
584
585 config SCSI_IN2000
586 tristate "Always IN2000 SCSI support"
587 depends on ISA && SCSI
588 help
589 This is support for an ISA bus SCSI host adapter. You'll find more
590 information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
591 out of the box, you may have to change the jumpers for IRQ or
592 address selection.
593
594 To compile this driver as a module, choose M here: the
595 module will be called in2000.
596
597 config SCSI_ARCMSR
598 tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
599 depends on PCI && SCSI
600 help
601 This driver supports all of ARECA's SATA/SAS RAID controller cards.
602 This is an ARECA-maintained driver by Erich Chen.
603 If you have any problems, please mail to: <erich@areca.com.tw>.
604 Areca supports Linux RAID config tools.
605 Please link <http://www.areca.com.tw>
606
607 To compile this driver as a module, choose M here: the
608 module will be called arcmsr (modprobe arcmsr).
609
610 config SCSI_ARCMSR_AER
611 bool "Enable PCI Error Recovery Capability in Areca Driver(ARCMSR)"
612 depends on SCSI_ARCMSR && PCIEAER
613 default n
614 help
615 The advanced error reporting(AER) capability is "NOT" provided by
616 ARC1200/1201/1202 SATA RAID controllers cards.
617 If your card is one of ARC1200/1201/1202, please use the default setting, n.
618 If your card is other models, you could pick it
619 on condition that the kernel version is greater than 2.6.19.
620 This function is maintained driver by Nick Cheng. If you have any
621 problems or suggestion, you are welcome to contact with <nick.cheng@areca.com.tw>.
622 To enable this function, choose Y here.
623
624 source "drivers/scsi/megaraid/Kconfig.megaraid"
625 source "drivers/scsi/mpt2sas/Kconfig"
626
627 config SCSI_HPTIOP
628 tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
629 depends on SCSI && PCI
630 help
631 This option enables support for HighPoint RocketRAID 3xxx/4xxx
632 controllers.
633
634 To compile this driver as a module, choose M here; the module
635 will be called hptiop. If unsure, say N.
636
637 config SCSI_BUSLOGIC
638 tristate "BusLogic SCSI support"
639 depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
640 ---help---
641 This is support for BusLogic MultiMaster and FlashPoint SCSI Host
642 Adapters. Consult the SCSI-HOWTO, available from
643 <http://www.tldp.org/docs.html#howto>, and the files
644 <file:Documentation/scsi/BusLogic.txt> and
645 <file:Documentation/scsi/FlashPoint.txt> for more information.
646 Note that support for FlashPoint is only available for 32-bit
647 x86 configurations.
648
649 To compile this driver as a module, choose M here: the
650 module will be called BusLogic.
651
652 config SCSI_FLASHPOINT
653 bool "FlashPoint support"
654 depends on SCSI_BUSLOGIC && PCI && X86_32
655 help
656 This option allows you to add FlashPoint support to the
657 BusLogic SCSI driver. The FlashPoint SCCB Manager code is
658 substantial, so users of MultiMaster Host Adapters may not
659 wish to include it.
660
661 config VMWARE_PVSCSI
662 tristate "VMware PVSCSI driver support"
663 depends on PCI && SCSI && X86
664 help
665 This driver supports VMware's para virtualized SCSI HBA.
666 To compile this driver as a module, choose M here: the
667 module will be called vmw_pvscsi.
668
669 config LIBFC
670 tristate "LibFC module"
671 select SCSI_FC_ATTRS
672 select CRC32
673 ---help---
674 Fibre Channel library module
675
676 config LIBFCOE
677 tristate "LibFCoE module"
678 select LIBFC
679 ---help---
680 Library for Fibre Channel over Ethernet module
681
682 config FCOE
683 tristate "FCoE module"
684 depends on PCI
685 select LIBFCOE
686 ---help---
687 Fibre Channel over Ethernet module
688
689 config FCOE_FNIC
690 tristate "Cisco FNIC Driver"
691 depends on PCI && X86
692 select LIBFCOE
693 help
694 This is support for the Cisco PCI-Express FCoE HBA.
695
696 To compile this driver as a module, choose M here and read
697 <file:Documentation/scsi/scsi.txt>.
698 The module will be called fnic.
699
700 config SCSI_DMX3191D
701 tristate "DMX3191D SCSI support"
702 depends on PCI && SCSI
703 select SCSI_SPI_ATTRS
704 help
705 This is support for Domex DMX3191D SCSI Host Adapters.
706
707 To compile this driver as a module, choose M here: the
708 module will be called dmx3191d.
709
710 config SCSI_DTC3280
711 tristate "DTC3180/3280 SCSI support"
712 depends on ISA && SCSI
713 select SCSI_SPI_ATTRS
714 select CHECK_SIGNATURE
715 help
716 This is support for DTC 3180/3280 SCSI Host Adapters. Please read
717 the SCSI-HOWTO, available from
718 <http://www.tldp.org/docs.html#howto>, and the file
719 <file:Documentation/scsi/dtc3x80.txt>.
720
721 To compile this driver as a module, choose M here: the
722 module will be called dtc.
723
724 config SCSI_EATA
725 tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
726 depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
727 ---help---
728 This driver supports all EATA/DMA-compliant SCSI host adapters. DPT
729 ISA and all EISA I/O addresses are probed looking for the "EATA"
730 signature. The addresses of all the PCI SCSI controllers reported
731 by the PCI subsystem are probed as well.
732
733 You want to read the start of <file:drivers/scsi/eata.c> and the
734 SCSI-HOWTO, available from
735 <http://www.tldp.org/docs.html#howto>.
736
737 To compile this driver as a module, choose M here: the
738 module will be called eata.
739
740 config SCSI_EATA_TAGGED_QUEUE
741 bool "enable tagged command queueing"
742 depends on SCSI_EATA
743 help
744 This is a feature of SCSI-2 which improves performance: the host
745 adapter can send several SCSI commands to a device's queue even if
746 previous commands haven't finished yet.
747 This is equivalent to the "eata=tc:y" boot option.
748
749 config SCSI_EATA_LINKED_COMMANDS
750 bool "enable elevator sorting"
751 depends on SCSI_EATA
752 help
753 This option enables elevator sorting for all probed SCSI disks and
754 CD-ROMs. It definitely reduces the average seek distance when doing
755 random seeks, but this does not necessarily result in a noticeable
756 performance improvement: your mileage may vary...
757 This is equivalent to the "eata=lc:y" boot option.
758
759 config SCSI_EATA_MAX_TAGS
760 int "maximum number of queued commands"
761 depends on SCSI_EATA
762 default "16"
763 help
764 This specifies how many SCSI commands can be maximally queued for
765 each probed SCSI device. You should reduce the default value of 16
766 only if you have disks with buggy or limited tagged command support.
767 Minimum is 2 and maximum is 62. This value is also the window size
768 used by the elevator sorting option above. The effective value used
769 by the driver for each probed SCSI device is reported at boot time.
770 This is equivalent to the "eata=mq:8" boot option.
771
772 config SCSI_EATA_PIO
773 tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
774 depends on (ISA || EISA || PCI) && SCSI && BROKEN
775 ---help---
776 This driver supports all EATA-PIO protocol compliant SCSI Host
777 Adapters like the DPT PM2001 and the PM2012A. EATA-DMA compliant
778 host adapters could also use this driver but are discouraged from
779 doing so, since this driver only supports hard disks and lacks
780 numerous features. You might want to have a look at the SCSI-HOWTO,
781 available from <http://www.tldp.org/docs.html#howto>.
782
783 To compile this driver as a module, choose M here: the
784 module will be called eata_pio.
785
786 config SCSI_FUTURE_DOMAIN
787 tristate "Future Domain 16xx SCSI/AHA-2920A support"
788 depends on (ISA || PCI) && SCSI
789 select CHECK_SIGNATURE
790 ---help---
791 This is support for Future Domain's 16-bit SCSI host adapters
792 (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
793 other adapters based on the Future Domain chipsets (Quantum
794 ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
795 It is explained in section 3.7 of the SCSI-HOWTO, available from
796 <http://www.tldp.org/docs.html#howto>.
797
798 NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
799 and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
800 controller support"). This Future Domain driver works with the older
801 Adaptec AHA-2920A boards with a Future Domain chip on them.
802
803 To compile this driver as a module, choose M here: the
804 module will be called fdomain.
805
806 config SCSI_FD_MCS
807 tristate "Future Domain MCS-600/700 SCSI support"
808 depends on MCA_LEGACY && SCSI
809 ---help---
810 This is support for Future Domain MCS 600/700 MCA SCSI adapters.
811 Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
812 is identical to the MCS 700 and hence also supported by this driver.
813 This driver also supports the Reply SB16/SCSI card (the SCSI part).
814 It supports multiple adapters in the same system.
815
816 To compile this driver as a module, choose M here: the
817 module will be called fd_mcs.
818
819 config SCSI_GDTH
820 tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
821 depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
822 ---help---
823 Formerly called GDT SCSI Disk Array Controller Support.
824
825 This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI)
826 manufactured by Intel Corporation/ICP vortex GmbH. It is documented
827 in the kernel source in <file:drivers/scsi/gdth.c> and
828 <file:drivers/scsi/gdth.h>.
829
830 To compile this driver as a module, choose M here: the
831 module will be called gdth.
832
833 config SCSI_ISCI
834 tristate "Intel(R) C600 Series Chipset SAS Controller"
835 depends on PCI && SCSI
836 depends on X86
837 # (temporary): known alpha quality driver
838 depends on EXPERIMENTAL
839 select SCSI_SAS_LIBSAS
840 select SCSI_SAS_HOST_SMP
841 ---help---
842 This driver supports the 6Gb/s SAS capabilities of the storage
843 control unit found in the Intel(R) C600 series chipset.
844
845 The experimental tag will be removed after the driver exits alpha
846
847 config SCSI_GENERIC_NCR5380
848 tristate "Generic NCR5380/53c400 SCSI PIO support"
849 depends on ISA && SCSI
850 select SCSI_SPI_ATTRS
851 ---help---
852 This is a driver for the old NCR 53c80 series of SCSI controllers
853 on boards using PIO. Most boards such as the Trantor T130 fit this
854 category, along with a large number of ISA 8bit controllers shipped
855 for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
856 you should select the specific driver for that card rather than
857 generic 5380 support.
858
859 It is explained in section 3.8 of the SCSI-HOWTO, available from
860 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
861 of the box, you may have to change some settings in
862 <file:drivers/scsi/g_NCR5380.h>.
863
864 To compile this driver as a module, choose M here: the
865 module will be called g_NCR5380.
866
867 config SCSI_GENERIC_NCR5380_MMIO
868 tristate "Generic NCR5380/53c400 SCSI MMIO support"
869 depends on ISA && SCSI
870 select SCSI_SPI_ATTRS
871 ---help---
872 This is a driver for the old NCR 53c80 series of SCSI controllers
873 on boards using memory mapped I/O.
874 It is explained in section 3.8 of the SCSI-HOWTO, available from
875 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
876 of the box, you may have to change some settings in
877 <file:drivers/scsi/g_NCR5380.h>.
878
879 To compile this driver as a module, choose M here: the
880 module will be called g_NCR5380_mmio.
881
882 config SCSI_GENERIC_NCR53C400
883 bool "Enable NCR53c400 extensions"
884 depends on SCSI_GENERIC_NCR5380
885 help
886 This enables certain optimizations for the NCR53c400 SCSI cards.
887 You might as well try it out. Note that this driver will only probe
888 for the Trantor T130B in its default configuration; you might have
889 to pass a command line option to the kernel at boot time if it does
890 not detect your card. See the file
891 <file:Documentation/scsi/g_NCR5380.txt> for details.
892
893 config SCSI_IBMMCA
894 tristate "IBMMCA SCSI support"
895 depends on MCA && SCSI
896 ---help---
897 This is support for the IBM SCSI adapter found in many of the PS/2
898 series computers. These machines have an MCA bus, so you need to
899 answer Y to "MCA support" as well and read
900 <file:Documentation/mca.txt>.
901
902 If the adapter isn't found during boot (a common problem for models
903 56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
904 option, where <pun> is the id of the SCSI subsystem (usually 7, but
905 if that doesn't work check your reference diskette). Owners of
906 model 95 with a LED-matrix-display can in addition activate some
907 activity info like under OS/2, but more informative, by setting
908 'ibmmcascsi=display' as an additional kernel parameter. Try "man
909 bootparam" or see the documentation of your boot loader about how to
910 pass options to the kernel.
911
912 To compile this driver as a module, choose M here: the
913 module will be called ibmmca.
914
915 config IBMMCA_SCSI_ORDER_STANDARD
916 bool "Standard SCSI-order"
917 depends on SCSI_IBMMCA
918 ---help---
919 In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
920 are assigned to the drive letters, starting with the lowest SCSI-id
921 (physical number -- pun) to be drive C:, as seen from DOS and
922 similar operating systems. When looking into papers describing the
923 ANSI-SCSI-standard, this assignment of drives appears to be wrong.
924 The SCSI-standard follows a hardware-hierarchy which says that id 7
925 has the highest priority and id 0 the lowest. Therefore, the host
926 adapters are still today everywhere placed as SCSI-id 7 by default.
927 In the SCSI-standard, the drive letters express the priority of the
928 disk. C: should be the hard disk, or a partition on it, with the
929 highest priority. This must therefore be the disk with the highest
930 SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
931 original definition of the SCSI-standard as also industrial- and
932 process-control-machines, like VME-CPUs running under realtime-OSes
933 (e.g. LynxOS, OS9) do.
934
935 If you like to run Linux on your MCA-machine with the same
936 assignment of hard disks as seen from e.g. DOS or OS/2 on your
937 machine, which is in addition conformant to the SCSI-standard, you
938 must say Y here. This is also necessary for MCA-Linux users who want
939 to keep downward compatibility to older releases of the
940 IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
941 June 1997).
942
943 If you like to have the lowest SCSI-id assigned as drive C:, as
944 modern SCSI-BIOSes do, which does not conform to the standard, but
945 is widespread and common in the PC-world of today, you must say N
946 here. If unsure, say Y.
947
948 config IBMMCA_SCSI_DEV_RESET
949 bool "Reset SCSI-devices at boottime"
950 depends on SCSI_IBMMCA
951 ---help---
952 By default, SCSI-devices are reset when the machine is powered on.
953 However, some devices exist, like special-control-devices,
954 SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
955 not reset when switched on. If you say Y here, each device connected
956 to your SCSI-bus will be issued a reset-command after it has been
957 probed, while the kernel is booting. This may cause problems with
958 more modern devices, like hard disks, which do not appreciate these
959 reset commands, and can cause your system to hang. So say Y only if
960 you know that one of your older devices needs it; N is the safe
961 answer.
962
963 config SCSI_IPS
964 tristate "IBM ServeRAID support"
965 depends on PCI && SCSI
966 ---help---
967 This is support for the IBM ServeRAID hardware RAID controllers.
968 See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
969 and <http://www-947.ibm.com/support/entry/portal/docdisplay?brand=5000008&lndocid=SERV-RAID>
970 for more information. If this driver does not work correctly
971 without modification please contact the author by email at
972 <ipslinux@adaptec.com>.
973
974 To compile this driver as a module, choose M here: the
975 module will be called ips.
976
977 config SCSI_IBMVSCSI
978 tristate "IBM Virtual SCSI support"
979 depends on PPC_PSERIES || PPC_ISERIES
980 select SCSI_SRP_ATTRS
981 select VIOPATH if PPC_ISERIES
982 help
983 This is the IBM POWER Virtual SCSI Client
984
985 To compile this driver as a module, choose M here: the
986 module will be called ibmvscsic.
987
988 config SCSI_IBMVSCSIS
989 tristate "IBM Virtual SCSI Server support"
990 depends on PPC_PSERIES && SCSI_SRP && SCSI_SRP_TGT_ATTRS
991 help
992 This is the SRP target driver for IBM pSeries virtual environments.
993
994 The userspace component needed to initialize the driver and
995 documentation can be found:
996
997 http://stgt.berlios.de/
998
999 To compile this driver as a module, choose M here: the
1000 module will be called ibmvstgt.
1001
1002 config SCSI_IBMVFC
1003 tristate "IBM Virtual FC support"
1004 depends on PPC_PSERIES && SCSI
1005 select SCSI_FC_ATTRS
1006 help
1007 This is the IBM POWER Virtual FC Client
1008
1009 To compile this driver as a module, choose M here: the
1010 module will be called ibmvfc.
1011
1012 config SCSI_IBMVFC_TRACE
1013 bool "enable driver internal trace"
1014 depends on SCSI_IBMVFC
1015 default y
1016 help
1017 If you say Y here, the driver will trace all commands issued
1018 to the adapter. Performance impact is minimal. Trace can be
1019 dumped using /sys/class/scsi_host/hostXX/trace.
1020
1021 config SCSI_INITIO
1022 tristate "Initio 9100U(W) support"
1023 depends on PCI && SCSI
1024 help
1025 This is support for the Initio 91XXU(W) SCSI host adapter. Please
1026 read the SCSI-HOWTO, available from
1027 <http://www.tldp.org/docs.html#howto>.
1028
1029 To compile this driver as a module, choose M here: the
1030 module will be called initio.
1031
1032 config SCSI_INIA100
1033 tristate "Initio INI-A100U2W support"
1034 depends on PCI && SCSI
1035 help
1036 This is support for the Initio INI-A100U2W SCSI host adapter.
1037 Please read the SCSI-HOWTO, available from
1038 <http://www.tldp.org/docs.html#howto>.
1039
1040 To compile this driver as a module, choose M here: the
1041 module will be called a100u2w.
1042
1043 config SCSI_PPA
1044 tristate "IOMEGA parallel port (ppa - older drives)"
1045 depends on SCSI && PARPORT_PC
1046 ---help---
1047 This driver supports older versions of IOMEGA's parallel port ZIP
1048 drive (a 100 MB removable media device).
1049
1050 Note that you can say N here if you have the SCSI version of the ZIP
1051 drive: it will be supported automatically if you said Y to the
1052 generic "SCSI disk support", above.
1053
1054 If you have the ZIP Plus drive or a more recent parallel port ZIP
1055 drive (if the supplied cable with the drive is labeled "AutoDetect")
1056 then you should say N here and Y to "IOMEGA parallel port (imm -
1057 newer drives)", below.
1058
1059 For more information about this driver and how to use it you should
1060 read the file <file:Documentation/scsi/ppa.txt>. You should also read
1061 the SCSI-HOWTO, which is available from
1062 <http://www.tldp.org/docs.html#howto>. If you use this driver,
1063 you will still be able to use the parallel port for other tasks,
1064 such as a printer; it is safe to compile both drivers into the
1065 kernel.
1066
1067 To compile this driver as a module, choose M here: the
1068 module will be called ppa.
1069
1070 config SCSI_IMM
1071 tristate "IOMEGA parallel port (imm - newer drives)"
1072 depends on SCSI && PARPORT_PC
1073 ---help---
1074 This driver supports newer versions of IOMEGA's parallel port ZIP
1075 drive (a 100 MB removable media device).
1076
1077 Note that you can say N here if you have the SCSI version of the ZIP
1078 drive: it will be supported automatically if you said Y to the
1079 generic "SCSI disk support", above.
1080
1081 If you have the ZIP Plus drive or a more recent parallel port ZIP
1082 drive (if the supplied cable with the drive is labeled "AutoDetect")
1083 then you should say Y here; if you have an older ZIP drive, say N
1084 here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
1085
1086 For more information about this driver and how to use it you should
1087 read the file <file:Documentation/scsi/ppa.txt>. You should also read
1088 the SCSI-HOWTO, which is available from
1089 <http://www.tldp.org/docs.html#howto>. If you use this driver,
1090 you will still be able to use the parallel port for other tasks,
1091 such as a printer; it is safe to compile both drivers into the
1092 kernel.
1093
1094 To compile this driver as a module, choose M here: the
1095 module will be called imm.
1096
1097 config SCSI_IZIP_EPP16
1098 bool "ppa/imm option - Use slow (but safe) EPP-16"
1099 depends on SCSI_PPA || SCSI_IMM
1100 ---help---
1101 EPP (Enhanced Parallel Port) is a standard for parallel ports which
1102 allows them to act as expansion buses that can handle up to 64
1103 peripheral devices.
1104
1105 Some parallel port chipsets are slower than their motherboard, and
1106 so we have to control the state of the chipset's FIFO queue every
1107 now and then to avoid data loss. This will be done if you say Y
1108 here.
1109
1110 Generally, saying Y is the safe option and slows things down a bit.
1111
1112 config SCSI_IZIP_SLOW_CTR
1113 bool "ppa/imm option - Assume slow parport control register"
1114 depends on SCSI_PPA || SCSI_IMM
1115 help
1116 Some parallel ports are known to have excessive delays between
1117 changing the parallel port control register and good data being
1118 available on the parallel port data/status register. This option
1119 forces a small delay (1.0 usec to be exact) after changing the
1120 control register to let things settle out. Enabling this option may
1121 result in a big drop in performance but some very old parallel ports
1122 (found in 386 vintage machines) will not work properly.
1123
1124 Generally, saying N is fine.
1125
1126 config SCSI_NCR53C406A
1127 tristate "NCR53c406a SCSI support"
1128 depends on ISA && SCSI
1129 help
1130 This is support for the NCR53c406a SCSI host adapter. For user
1131 configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
1132 in the kernel source. Also read the SCSI-HOWTO, available from
1133 <http://www.tldp.org/docs.html#howto>.
1134
1135 To compile this driver as a module, choose M here: the
1136 module will be called NCR53c406.
1137
1138 config SCSI_NCR_D700
1139 tristate "NCR Dual 700 MCA SCSI support"
1140 depends on MCA && SCSI
1141 select SCSI_SPI_ATTRS
1142 help
1143 This is a driver for the MicroChannel Dual 700 card produced by
1144 NCR and commonly used in 345x/35xx/4100 class machines. It always
1145 tries to negotiate sync and uses tag command queueing.
1146
1147 Unless you have an NCR manufactured machine, the chances are that
1148 you do not have this SCSI card, so say N.
1149
1150 config SCSI_LASI700
1151 tristate "HP Lasi SCSI support for 53c700/710"
1152 depends on GSC && SCSI
1153 select SCSI_SPI_ATTRS
1154 help
1155 This is a driver for the SCSI controller in the Lasi chip found in
1156 many PA-RISC workstations & servers. If you do not know whether you
1157 have a Lasi chip, it is safe to say "Y" here.
1158
1159 config SCSI_SNI_53C710
1160 tristate "SNI RM SCSI support for 53c710"
1161 depends on SNI_RM && SCSI
1162 select SCSI_SPI_ATTRS
1163 select 53C700_LE_ON_BE
1164 help
1165 This is a driver for the onboard SCSI controller found in older
1166 SNI RM workstations & servers.
1167
1168 config 53C700_LE_ON_BE
1169 bool
1170 depends on SCSI_LASI700
1171 default y
1172
1173 config SCSI_STEX
1174 tristate "Promise SuperTrak EX Series support"
1175 depends on PCI && SCSI
1176 ---help---
1177 This driver supports Promise SuperTrak EX series storage controllers.
1178
1179 Promise provides Linux RAID configuration utility for these
1180 controllers. Please visit <http://www.promise.com> to download.
1181
1182 To compile this driver as a module, choose M here: the
1183 module will be called stex.
1184
1185 config 53C700_BE_BUS
1186 bool
1187 depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
1188 default y
1189
1190 config SCSI_SYM53C8XX_2
1191 tristate "SYM53C8XX Version 2 SCSI support"
1192 depends on PCI && SCSI
1193 select SCSI_SPI_ATTRS
1194 ---help---
1195 This driver supports the whole NCR53C8XX/SYM53C8XX family of
1196 PCI-SCSI controllers. It also supports the subset of LSI53C10XX
1197 Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
1198 language. It does not support LSI53C10XX Ultra-320 PCI-X SCSI
1199 controllers; you need to use the Fusion MPT driver for that.
1200
1201 Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
1202 information.
1203
1204 config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
1205 int "DMA addressing mode"
1206 depends on SCSI_SYM53C8XX_2
1207 default "1"
1208 ---help---
1209 This option only applies to PCI-SCSI chips that are PCI DAC
1210 capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
1211
1212 When set to 0, the driver will program the chip to only perform
1213 32-bit DMA. When set to 1, the chip will be able to perform DMA
1214 to addresses up to 1TB. When set to 2, the driver supports the
1215 full 64-bit DMA address range, but can only address 16 segments
1216 of 4 GB each. This limits the total addressable range to 64 GB.
1217
1218 Most machines with less than 4GB of memory should use a setting
1219 of 0 for best performance. If your machine has 4GB of memory
1220 or more, you should set this option to 1 (the default).
1221
1222 The still experimental value 2 (64 bit DMA addressing with 16
1223 x 4GB segments limitation) can be used on systems that require
1224 PCI address bits past bit 39 to be set for the addressing of
1225 memory using PCI DAC cycles.
1226
1227 config SCSI_SYM53C8XX_DEFAULT_TAGS
1228 int "Default tagged command queue depth"
1229 depends on SCSI_SYM53C8XX_2
1230 default "16"
1231 help
1232 This is the default value of the command queue depth the
1233 driver will announce to the generic SCSI layer for devices
1234 that support tagged command queueing. This value can be changed
1235 from the boot command line. This is a soft limit that cannot
1236 exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
1237
1238 config SCSI_SYM53C8XX_MAX_TAGS
1239 int "Maximum number of queued commands"
1240 depends on SCSI_SYM53C8XX_2
1241 default "64"
1242 help
1243 This option allows you to specify the maximum number of commands
1244 that can be queued to any device, when tagged command queuing is
1245 possible. The driver supports up to 256 queued commands per device.
1246 This value is used as a compiled-in hard limit.
1247
1248 config SCSI_SYM53C8XX_MMIO
1249 bool "Use memory mapped IO"
1250 depends on SCSI_SYM53C8XX_2
1251 default y
1252 help
1253 Memory mapped IO is faster than Port IO. Most people should
1254 answer Y here, but some machines may have problems. If you have
1255 to answer N here, please report the problem to the maintainer.
1256
1257 config SCSI_IPR
1258 tristate "IBM Power Linux RAID adapter support"
1259 depends on PCI && SCSI && ATA
1260 select FW_LOADER
1261 ---help---
1262 This driver supports the IBM Power Linux family RAID adapters.
1263 This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
1264 as IBM iSeries 5702, 5703, 5709, and 570A.
1265
1266 config SCSI_IPR_TRACE
1267 bool "enable driver internal trace"
1268 depends on SCSI_IPR
1269 default y
1270 help
1271 If you say Y here, the driver will trace all commands issued
1272 to the adapter. Performance impact is minimal. Trace can be
1273 dumped using /sys/bus/class/scsi_host/hostXX/trace.
1274
1275 config SCSI_IPR_DUMP
1276 bool "enable adapter dump support"
1277 depends on SCSI_IPR
1278 default y
1279 help
1280 If you say Y here, the driver will support adapter crash dump.
1281 If you enable this support, the iprdump daemon can be used
1282 to capture adapter failure analysis information.
1283
1284 config SCSI_ZALON
1285 tristate "Zalon SCSI support"
1286 depends on GSC && SCSI
1287 select SCSI_SPI_ATTRS
1288 help
1289 The Zalon is a GSC/HSC bus interface chip that sits between the
1290 PA-RISC processor and the NCR 53c720 SCSI controller on C100,
1291 C110, J200, J210 and some D, K & R-class machines. It's also
1292 used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
1293 Say Y here if you have one of these machines or cards.
1294
1295 config SCSI_NCR_Q720
1296 tristate "NCR Quad 720 MCA SCSI support"
1297 depends on MCA && SCSI
1298 select SCSI_SPI_ATTRS
1299 help
1300 This is a driver for the MicroChannel Quad 720 card produced by
1301 NCR and commonly used in 345x/35xx/4100 class machines. It always
1302 tries to negotiate sync and uses tag command queueing.
1303
1304 Unless you have an NCR manufactured machine, the chances are that
1305 you do not have this SCSI card, so say N.
1306
1307 config SCSI_NCR53C8XX_DEFAULT_TAGS
1308 int "default tagged command queue depth"
1309 depends on SCSI_ZALON || SCSI_NCR_Q720
1310 default "8"
1311 ---help---
1312 "Tagged command queuing" is a feature of SCSI-2 which improves
1313 performance: the host adapter can send several SCSI commands to a
1314 device's queue even if previous commands haven't finished yet.
1315 Because the device is intelligent, it can optimize its operations
1316 (like head positioning) based on its own request queue. Some SCSI
1317 devices don't implement this properly; if you want to disable this
1318 feature, enter 0 or 1 here (it doesn't matter which).
1319
1320 The default value is 8 and should be supported by most hard disks.
1321 This value can be overridden from the boot command line using the
1322 'tags' option as follows (example):
1323 'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
1324 4, set queue depth to 16 for target 2 and target 3 on controller 0
1325 and set queue depth to 10 for target 0 / lun 2 on controller 1.
1326
1327 The normal answer therefore is to go with the default 8 and to use
1328 a boot command line option for devices that need to use a different
1329 command queue depth.
1330
1331 There is no safe option other than using good SCSI devices.
1332
1333 config SCSI_NCR53C8XX_MAX_TAGS
1334 int "maximum number of queued commands"
1335 depends on SCSI_ZALON || SCSI_NCR_Q720
1336 default "32"
1337 ---help---
1338 This option allows you to specify the maximum number of commands
1339 that can be queued to any device, when tagged command queuing is
1340 possible. The default value is 32. Minimum is 2, maximum is 64.
1341 Modern hard disks are able to support 64 tags and even more, but
1342 do not seem to be faster when more than 32 tags are being used.
1343
1344 So, the normal answer here is to go with the default value 32 unless
1345 you are using very large hard disks with large cache (>= 1 MB) that
1346 are able to take advantage of more than 32 tagged commands.
1347
1348 There is no safe option and the default answer is recommended.
1349
1350 config SCSI_NCR53C8XX_SYNC
1351 int "synchronous transfers frequency in MHz"
1352 depends on SCSI_ZALON || SCSI_NCR_Q720
1353 default "20"
1354 ---help---
1355 The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
1356 rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80. The numbers
1357 are respectively the maximum data transfer rates in mega-transfers
1358 per second for each class. For example, a FAST-20 Wide 16 device is
1359 able to transfer data at 20 million 16 bit packets per second for a
1360 total rate of 40 MB/s.
1361
1362 You may specify 0 if you want to only use asynchronous data
1363 transfers. This is the safest and slowest option. Otherwise, specify
1364 a value between 5 and 80, depending on the capability of your SCSI
1365 controller. The higher the number, the faster the data transfer.
1366 Note that 80 should normally be ok since the driver decreases the
1367 value automatically according to the controller's capabilities.
1368
1369 Your answer to this question is ignored for controllers with NVRAM,
1370 since the driver will get this information from the user set-up. It
1371 also can be overridden using a boot setup option, as follows
1372 (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
1373 for FAST-20 synchronous data transfer (20 mega-transfers per
1374 second).
1375
1376 The normal answer therefore is not to go with the default but to
1377 select the maximum value 80 allowing the driver to use the maximum
1378 value supported by each controller. If this causes problems with
1379 your SCSI devices, you should come back and decrease the value.
1380
1381 There is no safe option other than using good cabling, right
1382 terminations and SCSI conformant devices.
1383
1384 config SCSI_NCR53C8XX_NO_DISCONNECT
1385 bool "not allow targets to disconnect"
1386 depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
1387 help
1388 This option is only provided for safety if you suspect some SCSI
1389 device of yours to not support properly the target-disconnect
1390 feature. In that case, you would say Y here. In general however, to
1391 not allow targets to disconnect is not reasonable if there is more
1392 than 1 device on a SCSI bus. The normal answer therefore is N.
1393
1394 config SCSI_PAS16
1395 tristate "PAS16 SCSI support"
1396 depends on ISA && SCSI
1397 select SCSI_SPI_ATTRS
1398 ---help---
1399 This is support for a SCSI host adapter. It is explained in section
1400 3.10 of the SCSI-HOWTO, available from
1401 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
1402 of the box, you may have to change some settings in
1403 <file:drivers/scsi/pas16.h>.
1404
1405 To compile this driver as a module, choose M here: the
1406 module will be called pas16.
1407
1408 config SCSI_QLOGIC_FAS
1409 tristate "Qlogic FAS SCSI support"
1410 depends on ISA && SCSI
1411 ---help---
1412 This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
1413 FastSCSI! cards as well as any other card based on the FASXX chip
1414 (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
1415
1416 This driver does NOT support the PCI versions of these cards. The
1417 PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
1418 SCSI support"), below.
1419
1420 Information about this driver is contained in
1421 <file:Documentation/scsi/qlogicfas.txt>. You should also read the
1422 SCSI-HOWTO, available from
1423 <http://www.tldp.org/docs.html#howto>.
1424
1425 To compile this driver as a module, choose M here: the
1426 module will be called qlogicfas.
1427
1428 config SCSI_QLOGIC_1280
1429 tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
1430 depends on PCI && SCSI
1431 help
1432 Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
1433
1434 To compile this driver as a module, choose M here: the
1435 module will be called qla1280.
1436
1437 config SCSI_QLOGICPTI
1438 tristate "PTI Qlogic, ISP Driver"
1439 depends on SBUS && SCSI
1440 help
1441 This driver supports SBUS SCSI controllers from PTI or QLogic. These
1442 controllers are known under Solaris as qpti and in the openprom as
1443 PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
1444 driven by a different driver.
1445
1446 To compile this driver as a module, choose M here: the
1447 module will be called qlogicpti.
1448
1449 source "drivers/scsi/qla2xxx/Kconfig"
1450 source "drivers/scsi/qla4xxx/Kconfig"
1451
1452 config SCSI_LPFC
1453 tristate "Emulex LightPulse Fibre Channel Support"
1454 depends on PCI && SCSI
1455 select SCSI_FC_ATTRS
1456 help
1457 This lpfc driver supports the Emulex LightPulse
1458 Family of Fibre Channel PCI host adapters.
1459
1460 config SCSI_LPFC_DEBUG_FS
1461 bool "Emulex LightPulse Fibre Channel debugfs Support"
1462 depends on SCSI_LPFC && DEBUG_FS
1463 help
1464 This makes debugging information from the lpfc driver
1465 available via the debugfs filesystem.
1466
1467 config SCSI_SIM710
1468 tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
1469 depends on (EISA || MCA) && SCSI
1470 select SCSI_SPI_ATTRS
1471 ---help---
1472 This driver is for NCR53c710 based SCSI host adapters.
1473
1474 It currently supports Compaq EISA cards and NCR MCA cards
1475
1476 config SCSI_SYM53C416
1477 tristate "Symbios 53c416 SCSI support"
1478 depends on ISA && SCSI
1479 ---help---
1480 This is support for the sym53c416 SCSI host adapter, the SCSI
1481 adapter that comes with some HP scanners. This driver requires that
1482 the sym53c416 is configured first using some sort of PnP
1483 configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
1484 are using isapnp then you need to compile this driver as a module
1485 and then load it using insmod after isapnp has run. The parameters
1486 of the configured card(s) should be passed to the driver. The format
1487 is:
1488
1489 insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
1490
1491 To compile this driver as a module, choose M here: the
1492 module will be called sym53c416.
1493
1494 config SCSI_DC395x
1495 tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
1496 depends on PCI && SCSI && EXPERIMENTAL
1497 ---help---
1498 This driver supports PCI SCSI host adapters based on the ASIC
1499 TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
1500
1501 This driver works, but is still in experimental status. So better
1502 have a bootable disk and a backup in case of emergency.
1503
1504 Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
1505
1506 To compile this driver as a module, choose M here: the
1507 module will be called dc395x.
1508
1509 config SCSI_DC390T
1510 tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
1511 depends on PCI && SCSI
1512 ---help---
1513 This driver supports PCI SCSI host adapters based on the Am53C974A
1514 chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
1515 PCscsi/PCnet (Am53/79C974) solutions.
1516
1517 Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
1518
1519 Note that this driver does NOT support Tekram DC390W/U/F, which are
1520 based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
1521
1522 To compile this driver as a module, choose M here: the
1523 module will be called tmscsim.
1524
1525 config SCSI_T128
1526 tristate "Trantor T128/T128F/T228 SCSI support"
1527 depends on ISA && SCSI
1528 select SCSI_SPI_ATTRS
1529 select CHECK_SIGNATURE
1530 ---help---
1531 This is support for a SCSI host adapter. It is explained in section
1532 3.11 of the SCSI-HOWTO, available from
1533 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
1534 of the box, you may have to change some settings in
1535 <file:drivers/scsi/t128.h>. Note that Trantor was purchased by
1536 Adaptec, and some former Trantor products are being sold under the
1537 Adaptec name.
1538
1539 To compile this driver as a module, choose M here: the
1540 module will be called t128.
1541
1542 config SCSI_U14_34F
1543 tristate "UltraStor 14F/34F support"
1544 depends on ISA && SCSI && ISA_DMA_API
1545 ---help---
1546 This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
1547 The source at <file:drivers/scsi/u14-34f.c> contains some
1548 information about this hardware. If the driver doesn't work out of
1549 the box, you may have to change some settings in
1550 <file: drivers/scsi/u14-34f.c>. Read the SCSI-HOWTO, available from
1551 <http://www.tldp.org/docs.html#howto>. Note that there is also
1552 another driver for the same hardware: "UltraStor SCSI support",
1553 below. You should say Y to both only if you want 24F support as
1554 well.
1555
1556 To compile this driver as a module, choose M here: the
1557 module will be called u14-34f.
1558
1559 config SCSI_U14_34F_TAGGED_QUEUE
1560 bool "enable tagged command queueing"
1561 depends on SCSI_U14_34F
1562 help
1563 This is a feature of SCSI-2 which improves performance: the host
1564 adapter can send several SCSI commands to a device's queue even if
1565 previous commands haven't finished yet.
1566 This is equivalent to the "u14-34f=tc:y" boot option.
1567
1568 config SCSI_U14_34F_LINKED_COMMANDS
1569 bool "enable elevator sorting"
1570 depends on SCSI_U14_34F
1571 help
1572 This option enables elevator sorting for all probed SCSI disks and
1573 CD-ROMs. It definitely reduces the average seek distance when doing
1574 random seeks, but this does not necessarily result in a noticeable
1575 performance improvement: your mileage may vary...
1576 This is equivalent to the "u14-34f=lc:y" boot option.
1577
1578 config SCSI_U14_34F_MAX_TAGS
1579 int "maximum number of queued commands"
1580 depends on SCSI_U14_34F
1581 default "8"
1582 help
1583 This specifies how many SCSI commands can be maximally queued for
1584 each probed SCSI device. You should reduce the default value of 8
1585 only if you have disks with buggy or limited tagged command support.
1586 Minimum is 2 and maximum is 14. This value is also the window size
1587 used by the elevator sorting option above. The effective value used
1588 by the driver for each probed SCSI device is reported at boot time.
1589 This is equivalent to the "u14-34f=mq:8" boot option.
1590
1591 config SCSI_ULTRASTOR
1592 tristate "UltraStor SCSI support"
1593 depends on X86 && ISA && SCSI
1594 ---help---
1595 This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
1596 adapter family. This driver is explained in section 3.12 of the
1597 SCSI-HOWTO, available from
1598 <http://www.tldp.org/docs.html#howto>. If it doesn't work out
1599 of the box, you may have to change some settings in
1600 <file:drivers/scsi/ultrastor.h>.
1601
1602 Note that there is also another driver for the same hardware:
1603 "UltraStor 14F/34F support", above.
1604
1605 To compile this driver as a module, choose M here: the
1606 module will be called ultrastor.
1607
1608 config SCSI_NSP32
1609 tristate "Workbit NinjaSCSI-32Bi/UDE support"
1610 depends on PCI && SCSI && !64BIT
1611 help
1612 This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
1613 SCSI host adapter. Please read the SCSI-HOWTO, available from
1614 <http://www.tldp.org/docs.html#howto>.
1615
1616 To compile this driver as a module, choose M here: the
1617 module will be called nsp32.
1618
1619 config SCSI_DEBUG
1620 tristate "SCSI debugging host simulator"
1621 depends on SCSI
1622 select CRC_T10DIF
1623 help
1624 This is a host adapter simulator that can simulate multiple hosts
1625 each with multiple dummy SCSI devices (disks). It defaults to one
1626 host adapter with one dummy SCSI disk. Each dummy disk uses kernel
1627 RAM as storage (i.e. it is a ramdisk). To save space when multiple
1628 dummy disks are simulated, they share the same kernel RAM for
1629 their storage. See <http://sg.danny.cz/sg/sdebug26.html> for more
1630 information. This driver is primarily of use to those testing the
1631 SCSI and block subsystems. If unsure, say N.
1632
1633 config SCSI_MESH
1634 tristate "MESH (Power Mac internal SCSI) support"
1635 depends on PPC32 && PPC_PMAC && SCSI
1636 help
1637 Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
1638 SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
1639 other Power Macintoshes do). Say Y to include support for this SCSI
1640 adaptor.
1641
1642 To compile this driver as a module, choose M here: the
1643 module will be called mesh.
1644
1645 config SCSI_MESH_SYNC_RATE
1646 int "maximum synchronous transfer rate (MB/s) (0 = async)"
1647 depends on SCSI_MESH
1648 default "5"
1649 help
1650 On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
1651 drives a bus which is entirely internal to the machine (such as the
1652 7500, 7600, 8500, etc.), the MESH is capable of synchronous
1653 operation at up to 10 MB/s. On machines where the SCSI bus
1654 controlled by the MESH can have external devices connected, it is
1655 usually rated at 5 MB/s. 5 is a safe value here unless you know the
1656 MESH SCSI bus is internal only; in that case you can say 10. Say 0
1657 to disable synchronous operation.
1658
1659 config SCSI_MESH_RESET_DELAY_MS
1660 int "initial bus reset delay (ms) (0 = no reset)"
1661 depends on SCSI_MESH
1662 default "4000"
1663
1664 config SCSI_MAC53C94
1665 tristate "53C94 (Power Mac external SCSI) support"
1666 depends on PPC32 && PPC_PMAC && SCSI
1667 help
1668 On Power Macintoshes (and clones) with two SCSI buses, the external
1669 SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
1670 machines which only have one SCSI bus, such as the 7200, also use
1671 the 53C94. Say Y to include support for the 53C94.
1672
1673 To compile this driver as a module, choose M here: the
1674 module will be called mac53c94.
1675
1676 source "drivers/scsi/arm/Kconfig"
1677
1678 config JAZZ_ESP
1679 bool "MIPS JAZZ FAS216 SCSI support"
1680 depends on MACH_JAZZ && SCSI
1681 select SCSI_SPI_ATTRS
1682 help
1683 This is the driver for the onboard SCSI host adapter of MIPS Magnum
1684 4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
1685 systems.
1686
1687 config A3000_SCSI
1688 tristate "A3000 WD33C93A support"
1689 depends on AMIGA && SCSI
1690 help
1691 If you have an Amiga 3000 and have SCSI devices connected to the
1692 built-in SCSI controller, say Y. Otherwise, say N.
1693
1694 To compile this driver as a module, choose M here: the
1695 module will be called a3000.
1696
1697 config A2091_SCSI
1698 tristate "A2091/A590 WD33C93A support"
1699 depends on ZORRO && SCSI
1700 help
1701 If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
1702 say N.
1703
1704 To compile this driver as a module, choose M here: the
1705 module will be called a2091.
1706
1707 config GVP11_SCSI
1708 tristate "GVP Series II WD33C93A support"
1709 depends on ZORRO && SCSI
1710 ---help---
1711 If you have a Great Valley Products Series II SCSI controller,
1712 answer Y. Also say Y if you have a later model of GVP SCSI
1713 controller (such as the GVP A4008 or a Combo board). Otherwise,
1714 answer N. This driver does NOT work for the T-Rex series of
1715 accelerators from TekMagic and GVP-M.
1716
1717 To compile this driver as a module, choose M here: the
1718 module will be called gvp11.
1719
1720 config SCSI_A4000T
1721 tristate "A4000T NCR53c710 SCSI support (EXPERIMENTAL)"
1722 depends on AMIGA && SCSI && EXPERIMENTAL
1723 select SCSI_SPI_ATTRS
1724 help
1725 If you have an Amiga 4000T and have SCSI devices connected to the
1726 built-in SCSI controller, say Y. Otherwise, say N.
1727
1728 To compile this driver as a module, choose M here: the
1729 module will be called a4000t.
1730
1731 config SCSI_ZORRO7XX
1732 tristate "Zorro NCR53c710 SCSI support (EXPERIMENTAL)"
1733 depends on ZORRO && SCSI && EXPERIMENTAL
1734 select SCSI_SPI_ATTRS
1735 help
1736 Support for various NCR53c710-based SCSI controllers on Zorro
1737 expansion boards for the Amiga.
1738 This includes:
1739 - the Amiga 4091 Zorro III SCSI-2 controller,
1740 - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
1741 (info at
1742 <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
1743 - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
1744 accelerator card for the Amiga 1200,
1745 - the SCSI controller on the GVP Turbo 040/060 accelerator.
1746
1747 config ATARI_SCSI
1748 tristate "Atari native SCSI support"
1749 depends on ATARI && SCSI
1750 select SCSI_SPI_ATTRS
1751 select NVRAM
1752 ---help---
1753 If you have an Atari with built-in NCR5380 SCSI controller (TT,
1754 Falcon, ...) say Y to get it supported. Of course also, if you have
1755 a compatible SCSI controller (e.g. for Medusa).
1756
1757 To compile this driver as a module, choose M here: the
1758 module will be called atari_scsi.
1759
1760 This driver supports both styles of NCR integration into the
1761 system: the TT style (separate DMA), and the Falcon style (via
1762 ST-DMA, replacing ACSI). It does NOT support other schemes, like
1763 in the Hades (without DMA).
1764
1765 config ATARI_SCSI_TOSHIBA_DELAY
1766 bool "Long delays for Toshiba CD-ROMs"
1767 depends on ATARI_SCSI
1768 help
1769 This option increases the delay after a SCSI arbitration to
1770 accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
1771 use a Toshiba CD-ROM drive; otherwise, the option is not needed and
1772 would impact performance a bit, so say N.
1773
1774 config ATARI_SCSI_RESET_BOOT
1775 bool "Reset SCSI-devices at boottime"
1776 depends on ATARI_SCSI
1777 help
1778 Reset the devices on your Atari whenever it boots. This makes the
1779 boot process fractionally longer but may assist recovery from errors
1780 that leave the devices with SCSI operations partway completed.
1781
1782 config MAC_SCSI
1783 bool "Macintosh NCR5380 SCSI"
1784 depends on MAC && SCSI=y
1785 select SCSI_SPI_ATTRS
1786 help
1787 This is the NCR 5380 SCSI controller included on most of the 68030
1788 based Macintoshes. If you have one of these say Y and read the
1789 SCSI-HOWTO, available from
1790 <http://www.tldp.org/docs.html#howto>.
1791
1792 config SCSI_MAC_ESP
1793 tristate "Macintosh NCR53c9[46] SCSI"
1794 depends on MAC && SCSI
1795 select SCSI_SPI_ATTRS
1796 help
1797 This is the NCR 53c9x SCSI controller found on most of the 68040
1798 based Macintoshes.
1799
1800 To compile this driver as a module, choose M here: the module
1801 will be called mac_esp.
1802
1803 config MVME147_SCSI
1804 bool "WD33C93 SCSI driver for MVME147"
1805 depends on MVME147 && SCSI=y
1806 select SCSI_SPI_ATTRS
1807 help
1808 Support for the on-board SCSI controller on the Motorola MVME147
1809 single-board computer.
1810
1811 config MVME16x_SCSI
1812 tristate "NCR53C710 SCSI driver for MVME16x"
1813 depends on MVME16x && SCSI
1814 select SCSI_SPI_ATTRS
1815 help
1816 The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
1817 SCSI controller chip. Almost everyone using one of these boards
1818 will want to say Y to this question.
1819
1820 config BVME6000_SCSI
1821 tristate "NCR53C710 SCSI driver for BVME6000"
1822 depends on BVME6000 && SCSI
1823 select SCSI_SPI_ATTRS
1824 help
1825 The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
1826 SCSI controller chip. Almost everyone using one of these boards
1827 will want to say Y to this question.
1828
1829 config SUN3_SCSI
1830 tristate "Sun3 NCR5380 SCSI"
1831 depends on SUN3 && SCSI
1832 select SCSI_SPI_ATTRS
1833 help
1834 This option will enable support for the OBIO (onboard io) NCR5380
1835 SCSI controller found in the Sun 3/50 and 3/60, as well as for
1836 "Sun3" type VME scsi controllers also based on the NCR5380.
1837 General Linux information on the Sun 3 series (now discontinued)
1838 is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
1839
1840 config SUN3X_ESP
1841 bool "Sun3x ESP SCSI"
1842 depends on SUN3X && SCSI=y
1843 select SCSI_SPI_ATTRS
1844 help
1845 The ESP was an on-board SCSI controller used on Sun 3/80
1846 machines. Say Y here to compile in support for it.
1847
1848 config SCSI_SUNESP
1849 tristate "Sparc ESP Scsi Driver"
1850 depends on SBUS && SCSI
1851 select SCSI_SPI_ATTRS
1852 help
1853 This is the driver for the Sun ESP SCSI host adapter. The ESP
1854 chipset is present in most SPARC SBUS-based computers and
1855 supports the Emulex family of ESP SCSI chips (esp100, esp100A,
1856 esp236, fas101, fas236) as well as the Qlogic fas366 SCSI chip.
1857
1858 To compile this driver as a module, choose M here: the
1859 module will be called sun_esp.
1860
1861 config ZFCP
1862 tristate "FCP host bus adapter driver for IBM eServer zSeries"
1863 depends on S390 && QDIO && SCSI
1864 select SCSI_FC_ATTRS
1865 help
1866 If you want to access SCSI devices attached to your IBM eServer
1867 zSeries by means of Fibre Channel interfaces say Y.
1868 For details please refer to the documentation provided by IBM at
1869 <http://oss.software.ibm.com/developerworks/opensource/linux390>
1870
1871 This driver is also available as a module. This module will be
1872 called zfcp. If you want to compile it as a module, say M here
1873 and read <file:Documentation/kbuild/modules.txt>.
1874
1875 config ZFCP_DIF
1876 tristate "T10 DIF/DIX support for the zfcp driver (EXPERIMENTAL)"
1877 depends on ZFCP && EXPERIMENTAL
1878
1879 config SCSI_PMCRAID
1880 tristate "PMC SIERRA Linux MaxRAID adapter support"
1881 depends on PCI && SCSI && NET
1882 ---help---
1883 This driver supports the PMC SIERRA MaxRAID adapters.
1884
1885 config SCSI_PM8001
1886 tristate "PMC-Sierra SPC 8001 SAS/SATA Based Host Adapter driver"
1887 depends on PCI && SCSI
1888 select SCSI_SAS_LIBSAS
1889 help
1890 This driver supports PMC-Sierra PCIE SAS/SATA 8x6G SPC 8001 chip
1891 based host adapters.
1892
1893 config SCSI_SRP
1894 tristate "SCSI RDMA Protocol helper library"
1895 depends on SCSI && PCI
1896 select SCSI_TGT
1897 help
1898 If you wish to use SRP target drivers, say Y.
1899
1900 To compile this driver as a module, choose M here: the
1901 module will be called libsrp.
1902
1903 config SCSI_BFA_FC
1904 tristate "Brocade BFA Fibre Channel Support"
1905 depends on PCI && SCSI
1906 select SCSI_FC_ATTRS
1907 help
1908 This bfa driver supports all Brocade PCIe FC/FCOE host adapters.
1909
1910 To compile this driver as a module, choose M here. The module will
1911 be called bfa.
1912
1913 endif # SCSI_LOWLEVEL
1914
1915 source "drivers/scsi/pcmcia/Kconfig"
1916
1917 source "drivers/scsi/device_handler/Kconfig"
1918
1919 source "drivers/scsi/osd/Kconfig"
1920
1921 endmenu
This page took 0.094258 seconds and 5 git commands to generate.