1 # Reported 93/05/09 by Jim Wilson: IEEE single-precision FLT_MIN value gets
2 # assembled incorrectly. (Off by one ulp.)
5 set testname "IEEE FLT_MIN, single-precision"
7 gas_start "x930509a.s" "-al"
10 -re " 00 ?00 ?80 ?00\[ \]+.single" { pass $testname; set x 1 }
11 -re " 00 ?80 ?00 ?00\[ \]+.single" { pass $testname; set x 1 }
12 -re ".single" { fail $testname; set x 1 }
14 timeout { perror "timeout\n"; break }
19 if !$x then { fail "$testname (listing didn't match)" }
22 # C54x alignment/addressing is different, so the listing looks different
23 # float encoding is tested in c54x-specific tests
24 if { ![istarget vax*-*-*] && ![istarget *c54x*-*-*] } then {