2002-05-15 Nick Clifton <nickc@cambridge.redhat.com>
[deliverable/binutils-gdb.git] / gdb / infrun.c
index c935db86a7b978aaacaf53bd486c6f7dd266b46d..e9fea2a0ac7ce313f51ca6e1f6c448c393d0ba32 100644 (file)
@@ -1,4 +1,5 @@
-/* Target-struct-independent code to start (run) and stop an inferior process.
+/* Target-struct-independent code to start (run) and stop an inferior
+   process.
 
    Copyright 1986, 1987, 1988, 1989, 1990, 1991, 1992, 1993, 1994,
    1995, 1996, 1997, 1998, 1999, 2000, 2001, 2002 Free Software
@@ -114,15 +115,6 @@ static ptid_t previous_inferior_ptid;
 
 static int may_follow_exec = MAY_FOLLOW_EXEC;
 
-/* GET_LONGJMP_TARGET returns the PC at which longjmp() will resume the
-   program.  It needs to examine the jmp_buf argument and extract the PC
-   from it.  The return value is non-zero on success, zero otherwise. */
-
-#ifndef GET_LONGJMP_TARGET
-#define GET_LONGJMP_TARGET(PC_ADDR) 0
-#endif
-
-
 /* Dynamic function trampolines are similar to solib trampolines in that they
    are between the caller and the callee.  The difference is that when you
    enter a dynamic trampoline, you can't determine the callee's address.  Some
@@ -151,12 +143,12 @@ static int may_follow_exec = MAY_FOLLOW_EXEC;
    The simple approach is to single-step until control leaves the
    dynamic linker.
 
-   However, on some systems (e.g., Red Hat Linux 5.2) the dynamic
-   linker calls functions in the shared C library, so you can't tell
-   from the PC alone whether the dynamic linker is still running.  In
-   this case, we use a step-resume breakpoint to get us past the
-   dynamic linker, as if we were using "next" to step over a function
-   call.
+   However, on some systems (e.g., Red Hat's 5.2 distribution) the
+   dynamic linker calls functions in the shared C library, so you
+   can't tell from the PC alone whether the dynamic linker is still
+   running.  In this case, we use a step-resume breakpoint to get us
+   past the dynamic linker, as if we were using "next" to step over a
+   function call.
 
    IN_SOLIB_DYNSYM_RESOLVE_CODE says whether we're in the dynamic
    linker code or not.  Normally, this means we single-step.  However,
@@ -757,7 +749,15 @@ static const char *scheduler_enums[] =
 static void
 set_schedlock_func (char *args, int from_tty, struct cmd_list_element *c)
 {
-  if (c->type == set_cmd)
+  /* NOTE: cagney/2002-03-17: The add_show_from_set() function clones
+     the set command passed as a parameter.  The clone operation will
+     include (BUG?) any ``set'' command callback, if present.
+     Commands like ``info set'' call all the ``show'' command
+     callbacks.  Unfortunatly, for ``show'' commands cloned from
+     ``set'', this includes callbacks belonging to ``set'' commands.
+     Making this worse, this only occures if add_show_from_set() is
+     called after add_cmd_sfunc() (BUG?).  */
+  if (cmd_type (c) == set_cmd)
     if (!target_can_lock_scheduler)
       {
        scheduler_mode = schedlock_off;
@@ -2306,7 +2306,8 @@ handle_inferior_event (struct execution_control_state *ecs)
          disable_longjmp_breakpoint ();
          remove_breakpoints ();
          breakpoints_inserted = 0;
-         if (!GET_LONGJMP_TARGET (&jmp_buf_pc))
+         if (!GET_LONGJMP_TARGET_P ()
+             || !GET_LONGJMP_TARGET (&jmp_buf_pc))
            {
              keep_going (ecs);
              return;
@@ -2639,8 +2640,8 @@ handle_inferior_event (struct execution_control_state *ecs)
     ecs->update_step_sp = 1;
 
     /* Did we just take a signal?  */
-    if (IN_SIGTRAMP (stop_pc, ecs->stop_func_name)
-       && !IN_SIGTRAMP (prev_pc, prev_func_name)
+    if (PC_IN_SIGTRAMP (stop_pc, ecs->stop_func_name)
+       && !PC_IN_SIGTRAMP (prev_pc, prev_func_name)
        && INNER_THAN (read_sp (), step_sp))
       {
        /* We've just taken a signal; go until we are back to
@@ -2751,7 +2752,7 @@ handle_inferior_event (struct execution_control_state *ecs)
          {
            /* We're doing a "next".  */
 
-           if (IN_SIGTRAMP (stop_pc, ecs->stop_func_name)
+           if (PC_IN_SIGTRAMP (stop_pc, ecs->stop_func_name)
                && INNER_THAN (step_frame_address, read_sp()))
              /* We stepped out of a signal handler, and into its
                  calling trampoline.  This is misdetected as a
@@ -2960,8 +2961,8 @@ static void
 check_sigtramp2 (struct execution_control_state *ecs)
 {
   if (trap_expected
-      && IN_SIGTRAMP (stop_pc, ecs->stop_func_name)
-      && !IN_SIGTRAMP (prev_pc, prev_func_name)
+      && PC_IN_SIGTRAMP (stop_pc, ecs->stop_func_name)
+      && !PC_IN_SIGTRAMP (prev_pc, prev_func_name)
       && INNER_THAN (read_sp (), step_sp))
     {
       /* What has happened here is that we have just stepped the
@@ -3421,13 +3422,11 @@ and/or watchpoints.\n");
 
   target_terminal_ours ();
 
-  /* Look up the hook_stop and run it if it exists.  */
-
-  if (stop_command && stop_command->hook_pre)
-    {
-      catch_errors (hook_stop_stub, stop_command->hook_pre,
-                   "Error while running hook_stop:\n", RETURN_MASK_ALL);
-    }
+  /* Look up the hook_stop and run it (CLI internally handles problem
+     of stop_command's pre-hook not existing).  */
+  if (stop_command)
+    catch_errors (hook_stop_stub, stop_command,
+                 "Error while running hook_stop:\n", RETURN_MASK_ALL);
 
   if (!target_has_stack)
     {
@@ -3442,7 +3441,7 @@ and/or watchpoints.\n");
 
   if (!stop_stack_dummy)
     {
-      select_frame (get_current_frame (), 0);
+      select_frame (get_current_frame ());
 
       /* Print current location without a level number, if
          we have changed functions or hit a breakpoint.
@@ -3518,7 +3517,7 @@ and/or watchpoints.\n");
          Can't rely on restore_inferior_status because that only gets
          called if we don't stop in the called function.  */
       stop_pc = read_pc ();
-      select_frame (get_current_frame (), 0);
+      select_frame (get_current_frame ());
     }
 
 done:
@@ -3528,7 +3527,7 @@ done:
 static int
 hook_stop_stub (void *cmd)
 {
-  execute_user_command ((struct cmd_list_element *) cmd, 0);
+  execute_cmd_pre_hook ((struct cmd_list_element *) cmd);
   return (0);
 }
 \f
@@ -4025,7 +4024,7 @@ restore_selected_frame (void *args)
       return 0;
     }
 
-  select_frame (frame, fr->level);
+  select_frame (frame);
 
   return (1);
 }
@@ -4080,7 +4079,7 @@ restore_inferior_status (struct inferior_status *inf_status)
           frame.  */
 
 
-       select_frame (get_current_frame (), 0);
+       select_frame (get_current_frame ());
 
     }
 
This page took 0.025964 seconds and 4 git commands to generate.