ACPI / scan: use platform bus type by default for _HID enumeration
authorZhang Rui <rui.zhang@intel.com>
Fri, 30 May 2014 12:35:34 +0000 (14:35 +0200)
committerRafael J. Wysocki <rafael.j.wysocki@intel.com>
Fri, 30 May 2014 14:04:37 +0000 (16:04 +0200)
commit48459340b92b00ae1a75179f168ef20d3e61f264
tree46ee03d1984eba3272131619977ac3f2751c1ab0
parentd6ddaaac8f5c37ad84db3e6e019981f392389cf0
ACPI / scan: use platform bus type by default for _HID enumeration

Because of the growing demand for enumerating ACPI devices to
platform bus, change the code to enumerate ACPI device objects to
platform bus by default.  Namely, create platform devices for the
ACPI device objects that
 1. Have pnp.type.platform_id set (device objects with _HID currently).
 2. Do not have a scan handler attached.
 3. Are not SPI/I2C slave devices (that should be enumerated to the
    appropriate buses bus by their parent).

Signed-off-by: Zhang Rui <rui.zhang@intel.com>
[rjw: Subject and changelog, rebase and code cleanup]
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Reviewed-by: Mika Westerberg <mika.westerberg@linux.intel.com>
drivers/acpi/acpi_platform.c
drivers/acpi/scan.c
This page took 0.043571 seconds and 5 git commands to generate.