regulator: max8973: add DT binding details for junction warn temp
authorLaxman Dewangan <ldewangan@nvidia.com>
Wed, 13 Apr 2016 09:59:44 +0000 (15:29 +0530)
committerMark Brown <broonie@kernel.org>
Wed, 13 Apr 2016 16:19:26 +0000 (17:19 +0100)
commit19dd159ce8086293b70bd8e1aeebe06aff8d7df8
treecbd2fe5ef6d58626f22b9781795a568d039082a6
parentf55532a0c0b8bb6148f4e07853b876ef73bc69ca
regulator: max8973: add DT binding details for junction warn temp

The driver MAX8973 supports the driver for Maxim MAX77621.
MAX77621 supports the junction temp warning at 120 degC and
140 degC which is configurable. It generates alert signal when
junction temperature crosses these threshold.

Add DT properties and its binding details to make this
configuration from DT.

Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Documentation/devicetree/bindings/regulator/max8973-regulator.txt
This page took 0.024661 seconds and 5 git commands to generate.