iio: Update unit of the voltage scale in the documentation
authorLars-Peter Clausen <lars@metafoo.de>
Sat, 28 Sep 2013 09:31:00 +0000 (10:31 +0100)
committerJonathan Cameron <jic23@kernel.org>
Tue, 1 Oct 2013 15:19:14 +0000 (16:19 +0100)
commitc2b2db71014696207b24a2bafb2d26867f82dbed
treeaa11f71ac95500301ac7b2b176b18c6901eac095
parentbfbab2bcf9718ef5e778df8a746e5f4fb8ccd4f1
iio: Update unit of the voltage scale in the documentation

The documentation says that the result of raw * scale should be in microvolts,
but in reallity all drivers actually report the scale so that the result is in
millivolts. So update the documentation to match reallity.

Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Documentation/ABI/testing/sysfs-bus-iio
This page took 0.064166 seconds and 5 git commands to generate.