+power[1-*]_accuracy Accuracy of the power meter.
+ Unit: Percent
+ RO
+
+power[1-*]_alarm 1 if the system is drawing more power than the
+ cap allows; 0 otherwise. A poll notification is
+ sent to this file when the power use exceeds the
+ cap. This file only appears if the cap is known
+ to be enforced by hardware.
+ RO
+
+power[1-*]_cap If power use rises above this limit, the
+ system should take action to reduce power use.
+ A poll notification is sent to this file if the
+ cap is changed by the hardware. The *_cap
+ files only appear if the cap is known to be
+ enforced by hardware.
+ Unit: microWatt
+ RW
+
+power[1-*]_cap_hyst Margin of hysteresis built around capping and
+ notification.
+ Unit: microWatt
+ RW
+
+power[1-*]_cap_max Maximum cap that can be set.
+ Unit: microWatt
+ RO
+
+power[1-*]_cap_min Minimum cap that can be set.
+ Unit: microWatt
+ RO
+