NFC: trf7970a: Reread FIFO Status Register when draining FIFO
authorMark A. Greer <mgreer@animalcreek.com>
Tue, 2 Sep 2014 22:12:31 +0000 (15:12 -0700)
committerSamuel Ortiz <sameo@linux.intel.com>
Sun, 7 Sep 2014 21:13:44 +0000 (23:13 +0200)
Receiving an interrupt whose Interrupt Status Register
value has only the SRX bit set is supposed to mean that
all of the data from the tag has been received.  That
turns out to not be true so we need to reread the FIFO
Status Register to tell if there are any new bytes in
the FIFO.  If there are, continue receiving them; if
there aren't, assume that the receive is complete and
pass the data up.

Signed-off-by: Mark A. Greer <mgreer@animalcreek.com>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
drivers/nfc/trf7970a.c

index 6d2b06ddf191998712d2c1ee8b1cbe255e42a0c5..8c00827893f159a8fb8da270e4778951a167d3c1 100644 (file)
@@ -648,6 +648,21 @@ static void trf7970a_drain_fifo(struct trf7970a *trf, u8 status)
                status = TRF7970A_IRQ_STATUS_SRX;
        } else {
                trf->state = TRF7970A_ST_WAIT_FOR_RX_DATA_CONT;
+
+               ret = trf7970a_read(trf, TRF7970A_FIFO_STATUS, &fifo_bytes);
+               if (ret) {
+                       trf7970a_send_err_upstream(trf, ret);
+                       return;
+               }
+
+               fifo_bytes &= ~TRF7970A_FIFO_STATUS_OVERFLOW;
+
+               /* If there are bytes in the FIFO, set status to '0' so
+                * the if stmt below doesn't fire and the driver will wait
+                * for the trf7970a to generate another RX interrupt.
+                */
+               if (fifo_bytes)
+                       status = 0;
        }
 
 no_rx_data:
This page took 0.025745 seconds and 5 git commands to generate.