[SCSI] qla4xxx: Allow reset in link down case
authorHarish Zunjarrao <harish.zunjarrao@qlogic.com>
Fri, 23 Nov 2012 11:58:39 +0000 (06:58 -0500)
committerJames Bottomley <JBottomley@Parallels.com>
Tue, 29 Jan 2013 02:55:06 +0000 (13:55 +1100)
Issue:
Reset operation fails if port is in Link Down state

Fix:
Do not wait till HBA comes online after reset command is invoked.

Signed-off-by: Harish Zunjarrao <harish.zunjarrao@qlogic.com>
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
drivers/scsi/qla4xxx/ql4_os.c

index bfd1e68654ab3c8da951a8ad4836763cd6b7f8b3..47b908cacd012d015840cc50feeac4d51700eecb 100644 (file)
@@ -6006,14 +6006,6 @@ static int qla4xxx_host_reset(struct Scsi_Host *shost, int reset_type)
                goto exit_host_reset;
        }
 
-       rval = qla4xxx_wait_for_hba_online(ha);
-       if (rval != QLA_SUCCESS) {
-               DEBUG2(ql4_printk(KERN_INFO, ha, "%s: Unable to reset host "
-                                 "adapter\n", __func__));
-               rval = -EIO;
-               goto exit_host_reset;
-       }
-
        if (test_bit(DPC_RESET_HA, &ha->dpc_flags))
                goto recover_adapter;
 
This page took 0.028743 seconds and 5 git commands to generate.