From: Albert Lee Date: Sat, 25 Mar 2006 10:11:12 +0000 (+0800) Subject: [PATCH] libata-dev: fix the device err check sequence (respin) X-Git-Url: http://drtracing.org/?a=commitdiff_plain;h=71601958f73b952281f2b02e16d1f11c99ee0a8b;p=deliverable%2Flinux.git [PATCH] libata-dev: fix the device err check sequence (respin) Current irq-pio checks ERR bit and stops on ERR before it does anything else. This behavior doesn't look right. The DRQ bit should take higher precedence than the ERR bit. Changes: - Let the HSM do the data transfer whenever the device asks for DRQ bit, even if the ERR bit is set. - For DRQ=1 ERR=1, don't trust the data Signed-off-by: Albert Lee Signed-off-by: Jeff Garzik --- diff --git a/drivers/scsi/libata-core.c b/drivers/scsi/libata-core.c index d68f5d5b423a..59cb12993f95 100644 --- a/drivers/scsi/libata-core.c +++ b/drivers/scsi/libata-core.c @@ -3587,12 +3587,6 @@ static int ata_hsm_move(struct ata_port *ap, struct ata_queued_cmd *qc, */ WARN_ON(in_wq != ata_hsm_ok_in_wq(ap, qc)); - /* check error */ - if (unlikely(status & (ATA_ERR | ATA_DF))) { - qc->err_mask |= AC_ERR_DEV; - ap->hsm_task_state = HSM_ST_ERR; - } - fsm_start: DPRINTK("ata%u: protocol %d task_state %d (dev_stat 0x%X)\n", ap->id, qc->tf.protocol, ap->hsm_task_state, status); @@ -3615,6 +3609,17 @@ fsm_start: goto fsm_start; } + /* Device should not ask for data transfer (DRQ=1) + * when it finds something wrong. + * Anyway, we respect DRQ here and let HSM go on + * without changing hsm_task_state to HSM_ST_ERR. + */ + if (unlikely(status & (ATA_ERR | ATA_DF))) { + printk(KERN_WARNING "ata%d: DRQ=1 with device error, dev_stat 0x%X\n", + ap->id, status); + qc->err_mask |= AC_ERR_DEV; + } + /* Send the CDB (atapi) or the first data block (ata pio out). * During the state transition, interrupt handler shouldn't * be invoked before the data transfer is complete and @@ -3657,6 +3662,17 @@ fsm_start: goto fsm_start; } + /* Device should not ask for data transfer (DRQ=1) + * when it finds something wrong. + * Anyway, we respect DRQ here and let HSM go on + * without changing hsm_task_state to HSM_ST_ERR. + */ + if (unlikely(status & (ATA_ERR | ATA_DF))) { + printk(KERN_WARNING "ata%d: DRQ=1 with device error, dev_stat 0x%X\n", + ap->id, status); + qc->err_mask |= AC_ERR_DEV; + } + atapi_pio_bytes(qc); if (unlikely(ap->hsm_task_state == HSM_ST_ERR)) @@ -3672,6 +3688,22 @@ fsm_start: goto fsm_start; } + /* Some devices may ask for data transfer (DRQ=1) + * alone with ERR=1 for PIO reads. + * We respect DRQ here and let HSM go on without + * changing hsm_task_state to HSM_ST_ERR. + */ + if (unlikely(status & (ATA_ERR | ATA_DF))) { + /* For writes, ERR=1 DRQ=1 doesn't make + * sense since the data block has been + * transferred to the device. + */ + WARN_ON(qc->tf.flags & ATA_TFLAG_WRITE); + + /* data might be corrputed */ + qc->err_mask |= AC_ERR_DEV; + } + ata_pio_sectors(qc); if (ap->hsm_task_state == HSM_ST_LAST &&